Home
Products
Catalogs
About Us
Contact
Home
Products
Lab Equipment
Autoclaves
Freeze Dryers
Ice Makers
Laboratory Shaker
Spectrophotometer
Thermal Cycler
Amino Acid Analyzer
Autoclaves
Baths and Circulators
Cabinets
Centrifuge
Freezers
Freeze Dryers
Fume Hood
Muffle Furnace
Tube Furnace
Ice Makers
Incubator
Kjeldahl Systems
Laboratory Shakers and Mixers
Oven
Peristaltic Pump
Refrigerators
Spectrophotometer
Test Chamber
Thermal Cycler
Even More
Catalogs
About Us
Contact Us
+44 2080 043 608
info@labtron.co.uk
Home
Products
Lab Equipment
Autoclaves
Freeze Dryers
Ice Makers
Laboratory Shaker
Spectrophotometer
Thermal Cycler
Amino Acid Analyzer
Autoclaves
Baths and Circulators
Cabinets
Centrifuge
Freezers
Freeze Dryers
Fume Hood
Muffle Furnace
Tube Furnace
Ice Makers
Incubator
Kjeldahl Systems
Laboratory Shakers and Mixers
Oven
Peristaltic Pump
Refrigerators
Spectrophotometer
Test Chamber
Thermal Cycler
Even More
Catalogs
About Us
Contact Us
Quick Quote
×
Quick Quote Form
Name:
Email:
Product:
Message:
Home
Petroleum Testing
Amino Acid Analyzer
Autoclaves
Ethylene Oxide Sterilizer
Horizontal Autoclave
Medical Autoclave
Portable autoclave
Plasma Autoclave
Table Top Autoclave
Vertical Autoclave
Air Shower
Alloy Analyzer
Air Permeability Tester
Fabric Air Permeability Tester
Automatic Glassware Washer
Airborne Particle Counters
Dual Flow Airborne Particle Counter
Dust Monitor
Handheld Airborne Particle Counters
Portable Airborne Particle Counters
Baths and Circulators
Constant Temperature Water Bath
Circulating Water Bath
High Temperature Oil Bath
Heating Circulating Baths
Rapid Low-Temperature Cooling Circulating Bath
Refrigerated Thermostatic Bath
Refrigerated Thermostatic Bath and Heating Circulator
Stainless Steel Water Baths
Tissue Flotation Water Bath
Transparent Thermostatic Water Bath
Thermostatic Baths
Water Baths
Ball Mill Machine
Benchtop Ball Mill
Bottle Top Dispenser
Blood Bag Tube Sealer
Balances
Analytical Balance
Beam Balance
Density Balance
Electronic Balance
Floor Balance
Precision Balance
Textile Balance
Blood Collection Monitor
Biochemistry Analyzer
BLOOD THAW MACHINE
Cabinets
Class II Biosafety Cabinet
Cytotoxic Safety Cabinet
Clean Benches
Horizontal Laminar Flow Cabinets
PCR Cabinet
Vertical Laminar Flow Cabinets
Centrifuge
Cell Washing Centrifuge
High Speed Centrifuge
Haematocrit Centrifuge
Low Speed Centrifuge
Mini Centrifuge
PRP Centrifuge
Refrigerated Centrifuge
Vacuum Concentrator Centrifuge
Colorimeters
Benchtop Colorimeter
Colorimeter
Haze Meter
Spectral Colorimeter
Colony Counter
Automatic Colony Counter
Manual Colony Counter
Color Assessment Cabinet
CO2 Incubator
Air-jacketed CO
2
Incubator
Water-jacketed CO
2
Incubator
Chillers
Air Cooled Chillers
Recirculating Chiller
Water Chillers
Chromatography
GC-MS
Gas Chromatography
Ion Chromatography
Portable Ion Chromatograph
Drug Detector
Explosive Drug Detector
Trace Drug Detector
Differential Scanning Calorimeters
Dehumidifier
Dispersion Machine
Multi-Function Dispersion Machine
Differential Thermal Analyzers
Density Meter
Dosimeter
ESR Analyzer
Environmental Monitoring Equipments
Digital Differential Pressure Meter
Gas Detectors
Handheld Ozone Tester
Multifunctional Environmental Meter
Online Ozone Meter
UV-Absorption Ozone Meter
Electrophoresis System
Horizontal Electrophoresis System
Vertical Electrophoresis System
Elemental Analyzer
Elemental (CHN) Analyzer
Freezers
-25°C Chest Freezers
-25°C Upright Freezers
-40°C Chest Freezers
-40°C Upright Freezers
-60°C Chest Freezers
-86°C ULT Chest Freezers
-86°C ULT Upright Freezers
-105°C ULT Chest Freezers
-135°C ULT Chest Freezers
-150°C ULT Chest Freezers
-164°C ULT Chest Freezer
Blood Plasma Freezer
Liquid Nitrogen Freezer
Freeze Dryers
Laboratory Bench-top Freeze Dryer
Laboratory Floor model Freeze Dryer
Large Scale Freeze Dryer
Pilot Freeze Dryer
Fume Extractor
Fume Hood
Ductless Fumehood
Ducted Fumehood
PP Ducted Fumehood
Walk-in Fumehood
Fiber Analysis
Fiber Analyzer
Fluorometer
Fluorescence Analyzer
Fluorescence Mercury Analyzer
Flame Photometer
Flammability Tester
Gene Electroporator
Gel Strength Test System
Glassware Drying Cabinet
Gel Documentation
Chemiluminescence Imaging System
Gel Documentation System
Heating Mantle
Digital Display Heating Mantle
Multi-Position Heating Mantle
Hydrogen Peroxide Generator
Vapor Hydrogen Peroxide Generator
Hybridization System
FISH Hybridization System
Handheld Homogenizer
Hybridization Oven
HPLC
Analytical HPLC
Standard HPLC
Ice Makers
Cube Ice makers
Flake Ice Makers
Incubator
Anaerobic Incubator
Biochemical Incubator
Cooling Incubator
Drosophila Incubator
Dry Bath Incubator
Gel Card Incubator
Heating Incubator
Lighting Incubator
Portable Incubator
Roller Bottle Incubator
Shaking Incubator
Water Jacketed Incubator
IR Carbon Sulphur Analyzer
Jar Testers
Anaerobic Jar Tester
Flocculation Jar Tester
Kjeldahl Systems
Graphite Digester
Kjeldahl Analyzer
Latex Stability Tester
Laminar Flow Canopy
Lab Refrigerator-Freezer Combination
Laboratory Shakers and Mixers
3-D Gyratory Rockers
Double Sided Vertical Shaker
Microplate Shaker
Microplate Shaker Incubator
Multi-tube Vortex Mixer
Orbital Shaker
Orbital and Reciprocal Shaker
Platelet Shaker
Reciprocal Shaker
Sieve Shaker
See Saw Rocking Shaker
Tube Roller Mixer
Vortex Mixers
Water Bath Shakers
Wrist Shaker
Leather Softness Tester
Laser Theodolite
Liquid Handling
Micropipettes
Pipette Pump
Pipette Controller
Muffle Furnace
1100°C Muffle Furnace
1200°C Muffle Furnace
1250°C Muffle Furnace
1300°C Muffle Furnace
1400°C Muffle Furnace
1500°C Muffle Furnace
1550°C Muffle Furnace
1600°C Muffle Furnace
1700°C Muffle Furnace
1750°C Muffle Furnace
950°C Muffle Furnace
Melting Point Apparatus
LCD Screen Melting Point Apparatus
Touch Screen Melting Point Apparatus
Microscope
Atomic Force Microscope
Biological Microscope
Comparison Microscope
Digital Microscope
Educational Microscope
Fluorescence Microscope
Inverted Metallurgical Microscope
Inverted Fluorescence Microscope
Inverted Biological Microscopes
Metallurgical Microscope
Multi-Viewing Microscope
Microscopic Camera
Polarizing Microscope
Stereo Microscope
Microwave Digestion System
Metal Detector
Magnetic Stirrers and Hotplates
Digital Hotplate Stirrer
Digital Hotplates
Hotplate Magnetic Stirrer
Infrared Hotplate Stirrer
Infrared Hotplates
Multi-Position Magnetic Stirrer
Magnetic Stirrers
Overhead Stirrer
Microtome
Automatic Microtome
Rotary Microtome
Semi-automatic Microtome
Standard Microtome
Vibrating Microtome
Media Dispensing System
Automated Media Dispensing System
Moisture Analyzer
Grain Moisture Meter
Garment Moisture Meter
Hay Moisture Meter
Halogen Moisture Analyzer
Infrared Moisture Analyzer
Meat Moisture Meter
Microplate Reader & Washer
Microplate Reader
Microplate Washer
Milk Analyzers
Milk Analyzer
Milk Fat Analyzer
Nucleic Acid Purification System
Osmometer
Oven
Aging Oven
Commercial Microwave Oven
Drying Oven
Forced Air Drying Oven
Gravity Convection Oven
High Temperature Drying Oven
Vacuum Oven
Oil And Grease Analyzer
Oven Incubator
Opacity Meter
Paraffin Trimmer
Polarimeter
Automatic Polarimeter
Manual Polarimeter
Semi-automatic Polarimeter
Peristaltic Pump
Dispensing Peristaltic Pump
Intelligent Flow Peristaltic Pump
Industrial Peristaltic Pump
Variable Speed Peristaltic Pump
Pharmaceutical Testing
Dissolution Tester
Disintegration Tester
Friability Tester
Powder Flowability Tester
Syrup Filling Machine
Single Punch Tablet Press Machine
Tap Density Tester
Tablet Hardness Testers
Tablet Counting Machine
Particle Counter
Liquid Particle Counter
Petroleum Testing
Ash Content Tester
Automatic Tag Closed Flash Point Tester
Automatic Dielectric Tester
Automatic Softening Point Tester
Automatic Thermogravimetric Analyzer
Automatic Bomb Calorimeter
Acid and Alkali Tester
Aniline Test Equipment
Constant Temperature Needle Penetration Tester
Closed Cup Flash Point Tester
Demulsibility Characteristics Tester
Density Tester
Distillation Tester
Dropping Point Tester
Engler Viscometer
Existent Gum Tester
Foaming Characteristics Tester
Kinematics Viscometer
Low Temperature Tester
Mercaptan Sulfur Tester
Octane Number & Cetane Number Tester
Open Cup Flash Point Tester
Other Instrument
Oxidation Stability Tester
Oxygen Bomb Calorimeter
Penetrometer
Residue Carbon
Rotational Viscometer
Rust and Corrosion Tester
Specific Gravity Tester
Sulphur Content Tester
Vapor Pressure
Water Content Tester
Platelet Agitator and Incubator
Platelet Agitator
Platelet Incubator
Potentiometric Titrator
Automatic Potentiometric Titrator
Particle Size Analyzer
Image Particle Shape & Size Analyzer
Laser Particle Size Analyzer
Nano Particle Size Analyzer
Spray Particle Size Analyzer
Pathology Workstation
Plasma Extractor
Plate Sealer
Rotary Evaporator
Automatic Lifting Rotary Evaporator
Manual Lifting Rotary Evaporator
Vertical Condenser Rotary Evaporator
Refrigerators
+2 to +8℃ Medical Refrigerator
4 ℃ Blood Bank Refrigerator
Pharmacy Refrigerator
Portable Refrigerator
Refractometer
Benchtop Refractometer
Digital Refractometer
Handheld Refractometer
Portable Refractometers
Slide Dryer
Spectrometer
Atomic Fluorescence Spectrometer
Angular Spectrometer
FTIR Spectrometer
ICP Spectrometer
XRF Spectrometer
XRD Diffractometer
Sound Level Analysis
Sound Level Meter-Calibrator
Spectrophotometer
Atomic Absorption Spectrophotometer
Double Beam UV/Vis Spectrophotometer
Fluorescence Spectrophotometer
NIR Spectrophotometer
Nano Spectrophotometer
Portable Spectrophotometer
Single Beam UV/Visible Spectrophotometer
Table Top Spectrophotometer
Visible Spectrophotometer
Xenon Lamp Spectrophotometer
Sample Concentrator
Semi-automatic Bio-chemistry Analyzer
Safety Containment Cabinets
Corrosive Cabinets
Combustible Cabinets
Filtered Chemical Storage Cabinet
Flammable Cabinets
PPE Cabinets
Strong Acid and Alkali Chemical Storage Cabinet
Toxic Cabinets
Weak Acid and Alkali Chemical Storage Cabinet
Soxhlet Apparatus
Scintillation Counter
Liquid Scintillation Counter
Stomacher
Solar Powered Products
Solar Eco Freezer
Stroboscope
TOC Analyzer
Tube Furnace
Tachometer
Testing Instruments
NDT Testing Instruments
Other Testing Instruments
Paper Testing Instruments
Plastic Testing Instruments
Rubber Testing Instruments
Soil Testing Instruments
Test Chamber
Drug Test Chamber
Ozone Test Chamber
Plant Growth Chamber
Salt Spray Test Chamber
Sand Test Chamber
Temperature and Humidity Test Chamber
UV Test Chamber
Xenon Test Chamber
Thermal Cycler
Advanced PCR System
Advanced Thermal Cycler
Real Time PCR
Touch Thermal Cycler
Thermo-Shakers
Thermo Shaker Incubator
Thermo-Shaker Dry Bath
UV Analyzer
UV Analyzers
Ultrasonic Cleaner
Auto lift Industrial Cleaner
Digital Ultrasonic Cleaner
Industrial Ultrasonic Cleaner
Multifunction Ultrasonic Cleaner
Mechanical Heating Ultrasonic Cleaner
Power Adjustable Ultrasonic Cleaner
UV Air Sterilizer
UV Pass Box
UV Pass Box (with HEPA filters)
UV Pass Box (without HEPA Filters)
Ultrasonic Homogenizer
Automatic Ultrasonic Homogenizer
Ultrasonic Homogenizer (Sonicator)
Ultrasonic Homogenizer (Non-contact)
Vacuum Spin Coater
Vacuum Pycnometer
Vacuum Filtration Unit
Filtration unit with Flask
Manifold Vacuum Filtration Unit
Vacuum Packing machine
Benchtop Vacuum Packing machine
Vacuum Pump
Batch Transfer Hose Pump
Belt Drive Vacuum Pump
Diaphragm Vacuum Pump
Direct Drive Rotary Vane Vacuum Pump
Double Stage Rotary Vane Vacuum Pump
Liquid Suction Filtration Vacuum Pump
Mini Vacuum Pump
Rotary Vane Vacuum Pump
Single-stage Rotary Vane Vacuum Pump
Scroll Vacuum Pump
V-shell Blender
Viscometer
Cone Viscometers
Rotational Viscometers
Ubbelohde Viscometer
Wind Meter (Anemometer)
Water Purifier
Washer Disinfector
Water Testing
Benchtop Conductivity Meter
Benchtop Dissolved Oxygen Meter
Benchtop Ion Meter
Benchtop Water Hardness Meter
Benchtop Multi-parameter Water Quality Meter
BOD Meter
Conductivity Tester
Dissolved Oxygen Tester
Multi Parameter Water Quality Analyzer
ORP Tester
Online pH Controller
Online Dissolved Oxygen Controller
Online Conductivity Controller
pH Meter (Benchtop)
pH Tester
Portable Dissolve Oxygen Meter
Portable Multi Parameter Water Quality Meter
pH Meters (Portable)
Portable Water Hardness Meters
Portable Chlorine Meter
Portable Conductivity Meter
Salinity Tester
TDS Tester
Turbidity Meter
TSS Meter
Water Activity Meter
Water Distillers
Glass Water Distiller
Stainless Steel Water Distillers
Water Purification System
Deionized Water System
Radio Frequency Identification Water Purification System
Type I and Type III Water Purification System
Type II Water Purification System
Type III Water Purification System
UV Water Purification System
Water Purification System (Feed-specific)
X-Ray Machine
Portable X-Ray Machine
X-Ray Film Processor
Petroleum Testing
Acid and Alkali Tester
Automatic Bomb Calorimeter
Automatic Tag Closed Flash Point Tester
Ash Content Tester
Distillation Tester
Automatic Dielectric Tester
Aniline Test Equipment
Oxygen Bomb Calorimeter
Closed Cup Flash Point Tester
Other Instrument
Demulsibility Characteristics Tester
Density Tester
Dropping Point Tester
Existent Gum Tester
Engler Viscometer
Foaming Characteristics Tester
Kinematics Viscometer
Low Temperature Tester
Penetrometer
Mercaptan Sulfur Tester
Octane Number & Cetane Number Tester
Open Cup Flash Point Tester
Oxidation Stability Tester
Rust and Corrosion Tester
Residue Carbon
Rotational Viscometer
Specific Gravity Tester
Automatic Softening Point Tester
Sulphur Content Tester
Automatic Thermogravimetric Analyzer
Constant Temperature Needle Penetration Tester
Vapor Pressure
Water Content Tester
Water Soluble Acid and Alkali Tester LAAT-A10
Graduated flask : 100 ml,50 ml
Conical flask : 100ml
Separatory funnel : 250ml
Ambient temperature : (-10 )°C to 35 °C
Add to compare
Catalog
Acid Number and Acidity Tester LAAT-A11
Ambient temperature : ≤ 35 °C
Relative humidity : ≤ 85 %
Precision of titration tube : Scale division is 0.02 ml
Total power consumption : ≤ 1200 W
Add to compare
Catalog
Acid Number Tester LAAT-A12
Measurement range : ≥0.05 mg KOH/g
Potential measurement range : 0 to 1800.0 mV
Burette volume : 10 mL
Minimum titration volume : 0.001 ml
Add to compare
Catalog
Base Number Tester LAAT-A13
Volumetric analysis : Titration condensation: 0.1 N;
Controlling accuracy: ≤ ± 0.02 ml
Automatic acid titration : Titration condensation: 0.1 N;
Controlling accuracy: ≤ ± 0.1 pH
Automatic potential control : Titration condensation: 0.1 N;
Controlling accuracy: ≤ 10 mV
Ambient temperature : 0 ~ 35 ℃
Add to compare
Catalog
Automatic Bomb Calorimeter LABC-A10
Calorimeter type : Isoperibol
Temperature range : 5 to 40°C
Measurement range : 5 to 40 MJ/ kg
Operation Mode : The outer barrel temperature is constant
Add to compare
Catalog
Automatic Bomb Calorimeter LABC-A11
Calorimeter type : Isoperibol
Temperature range : 5 to 40°C
Measurement range : 5 to 40 MJ/ kg
Operation Mode : A. Outer barrel temperature follows room temperature change mode Or B. Outer barrel temperature constant mode
Add to compare
Catalog
Automatic Bomb Calorimeter LABC-B10
Calorimeter type : Isoperibol
Oxygen filling : Fully automatic oxygen filling & releasing, fully automatic bomb raising & lowering
Bomb volume : 250 ml
Analysis time : < 8 min full test process: <10 min
Add to compare
Catalog
Automatic Bomb Calorimeter LABC-B11
Calorimeter type : Isoperibol
Oxygen filling : Semi-automatic
Bomb volume : 282 ml
Analysis time : 15 to 25 min
Add to compare
Catalog
Automatic Tag Closed Flash Point Tester LACF-A10
Experimental temperature range : -50 to 70°C
Test sample volume : 50 ml
Ambient temperature range : 10 to 40°C
Humidity : ≤ 85%
Add to compare
Catalog
Ash Content Tester LACT-A10
Electric Muffle Furnace :
Temperature controller :
Electric heating plate :
Add to compare
Catalog
Automatic Distillation Apparatus LADA-A10
Heating power : 2 kW
Cooling power : 0.5 kW
Steam temperature : 0 to 400℃
Oven temperature : 0 to 500℃
Add to compare
Catalog
Distillation Tester LDT-A10
Graduated flasks : 10 ml and 100 ml
Scale division of graduated flask : 10 ml is 0.1 ml and 100 ml is 1 ml
Ambient temperature : (-10) °C ~ 35 °C
Relative humidity : ≤ 85 %
Add to compare
Catalog
Benzene Distillation Tester (Low Temperature) LDT-A11
Ambient temperature : -10°C to 35°C
Relative humidity : ≤ 85 %
Thermometer : Each one for 70°C to 90°C , 100°C to120°C , and 125°C to 150°C
Scale division : 0.1 ℃
Add to compare
Catalog
Distillation Tester LDT-A12
Graduated flasks : 100 ml
Scale division of graduated flask : 1 ml
Outer diameter of distillation flask : φ65
Refrigeration tube : φ14
Add to compare
Catalog
Vacuum Distillation Tester LDT-A13
Ambient temperature : 5 °C to 35 ℃
Relative humidity : ≤ 85 %
Cubage of buffer vessel : 1000 ml
Max. Residual pressure : ≤ 2 mm Hg
Add to compare
Catalog
Distillation Tester Front Type LDT-A14
Distillation flask : 125 mL
Ambient temperature : Room temperature to 35 °C
Relative humidity : ≤ 85 %
Thermometer : (-2 )°C to 300 ℃ and (-2) °C to 400 ℃
Add to compare
Catalog
Distillation Tester Dual Units LDT-A15
Graduated flasks : 100 ml
Scale division of graduated flask : 1ml
Distillation flask : 125 ml
Ambient temperature : ≤ 35 °C
Add to compare
Catalog
Distillation Tester (low temperature Double units) LDT-A16
Graduated flasks : 100 ml
Distillation flask : 125 ml
Ambient temperature : ≤ 35 °C
Relative humidity : ≤ 85 %
Add to compare
Catalog
Distillation Tester (low temperature single unit) LDT-A17
Graduated flasks : 100 ml
Distillation flask : 125 mL
Ambient temperature : ≤ 30 °C
Relative humidity : ≤ 85 %
Add to compare
Catalog
Automatic Dielectric Tester LADT-A10
Capacity : 2.0 kVA
Speed of voltage increase : 2 k V/ s
Voltage inspection accuracy : 0.01
Breakdown sensitivity : < 0.1 kV
Add to compare
Catalog
Aniline Point Tester LAPT-A10
Measurement range : Room temperature ~ 150°C
Stirring speed : 0 ~ 1200 r / min
Heating power : 25 W
Interior Dimension : 360 × 250 × 545 mm
Add to compare
Catalog
Aniline Point Tester LAPT-A11
Temperature controlling accuracy : ≤ 0.5 ℃
Temperature controlling range : Room temperature ~ 200 ℃
Power supply for illumination : 5 V
Power of motor : 2 kW
Add to compare
Catalog
Oxygen Bomb Calorimeter LBC-C20
Heat capacity : 14000 ~ 15000 J / K
Temperature measurement range : 10 ~ 35 ℃
Repeatability error : ≤ 0.2 % (Grade C)
Endured pressure in oxygen bomb : 20 MPa
Add to compare
Catalog
Oxygen Bomb Calorimeter LBC-C21
Temperature controlling range : 10 ℃ ~ 35 ℃
Temperature resolution : 0.001 ℃
Mean value of heat capacity : 15 kJ / K
Ambient temperature : 20 ℃ ± 5 ℃
Add to compare
Catalog
Oxygen Bomb Calorimeter LBC-C22
Temperature measurement range : 10 ~ 35 ℃
Repeatability error : ≤ 0.2 % (Grade C)
Endured pressure in oxygen bomb : 20 MPa
Operation environment temperature : 15 ~ 28 ℃
Add to compare
Catalog
PMCC Flash Point Tester LCFP-A10
Ambient temperature : ≤ 35 °C
Relative humidity : ≤ 85 %
Temperature range : 5 °C ~ 110 °C, Each scale division is 0.5 °C; 20 °C ~ 150 °C, Each scale division is 1.0 °C; 90 °C ~ 370 °C, Each scale division is 2 °C
Aperture of ignition device : 0.8 mm
Add to compare
Catalog
Automatic PMCC Flash Point Tester LCFP-A11
Ambient temperature : 10 °C ~ 40 °C
Relative humidity : ≤ 80 %
Measurement Range : Ambient Temperature ~ 250 °C
Flash Point : Lower than 104 °C , error is 2 °C; Higher than 104 °C , error is 6 °C
Add to compare
Catalog
Automatic PMCC Flash Point Tester LCFP-A13
Ambient temperature : 10 °C ~ 40 ℃
Relative humidity : ≤ 80 %
Ignition Mode : electron igniter / gas flame
Temperature range : Room Temperature ~ 300 ℃
Add to compare
Catalog
Color Tester LCT-A20
Light source : 220 V, 100 W
Temperature of grinding milk white light bulb : 2750 ± 50 K
Light hole( Φ14) : 26 pieces
Color comparing tube : Φ32 mm
Add to compare
Catalog
Insulating Oil Breakdown Voltage Tester LIBT-A23
Power supply : AC 220 V ± 5 % , 50Hz
Measurement range : 0 ~ 75 kV
Voltage rising rate : 3 kV ± 10 % / s
Distance between electrodes : 2.5 mm
Add to compare
Catalog
Mechanical Impurity Tester (Weight Method) LMIT-A21
Dimension : 390 x 260 x 590 mm
Total power consumption : ≤ 1200 W
Power supply : AC 220 V ± 10 %, 50 Hz
Heating power of water bath : 1000 W
Add to compare
Catalog
Wax Oil Content Tester LWCT-A22
Power supply : AC 220 V ± 10 %, 50 Hz
Temperature controlling range in water bath : RT ~ 90 ℃ ± 5 ℃
Cooling bath temperature : (-35) ℃ ± 1 ℃
Evaporation temperature : 35 ℃ ± 1 ℃
Add to compare
Catalog
Petroleum Oils and Synthetic Fluids Demulsibility Characteristics Tester LDCT-A10
Ambient temperature : Room temperature to 35 °C
Relative humidity : ≤ 85 %
Timing range : 1 s to 9 min 59 s
Temperature controlling range : Room temperature to 99.9 °C
Add to compare
Catalog
Petroleum Oils and Synthetic Fluids Demulsibility Characteristics Tester LDCT-A11
Ambient temperature : Room temperature to 35 °C
Relative humidity : ≤ 85 %
Temperature controlling range : Room temperature to 99.9 °C
Temperature controlling accuracy : ± 1 °C
Add to compare
Catalog
Density Tester LDMT-A10
Cubage of bath : Ф300 × 380 mm
Temperature controlling range : 0 °C ~ 100 °C
Temperature controlling accuracy : ± 0.2 °C
Temperature sensor : Industrial platinum resistance, Pt100
Add to compare
Catalog
Dropping Point Tester (Oil Bath) LDPT-A10
Beaker quantity : 600 ml
Ambient temperature : (-10) °C ~ 40 °C
Relative humidity : ≤ 85 %
Thermometer Measurement range : (-5) °C ~ 300 °C
Add to compare
Catalog
Dropping Point Tester (Air bath) LDPT-A11
Ambient temperature : ≤ 35 ℃
Relative humidity : ≤ 85 %
Heating power of electric furnace : 250 W × 2
Total power consumption : ≤ 700 W
Add to compare
Catalog
Existent Gum Tester LEGT- B30
Bath type : Oil bath
Bath capacity : 5000 ml ± 50 ml
Ambient temperature : Room temperature to 35 °C
Relative humidity : ≤ 85 %
Add to compare
Catalog
Existent Gum Tester LEGT- B31
Evaporation bath type and size : Aluminum block bath, φ260 × 130 mm
Holes for testing : 3 pieces
Size of holes for testing cylinder : φ51 × 70 mm
Flow rate display : Flow meter
Add to compare
Catalog
Existent Gum Tester LEGT- B32
Evaporation bath type and size : Aluminum bath φ260 × 130 mm
Holes for testing : 5 pieces
Size of holes for testing cylinder : φ51 × 70 mm
Working temperature : 160 ℃ ~ 165℃
Add to compare
Catalog
Engler Viscometer LEV-A10
Graduated Flask : 200 ± 0.2 ml
Standard Water Value : 51 ± 1 s
Temperature Range : 0 ~ 100 °C
Temperature Controlling Accuracy : ± 0.2 °C
Add to compare
Catalog
Engler Viscometer LEV-A11
Graduated Flask : 100 ml
Standard Water Value : 51 ± 1 s
Temperature Range : 0 ~ 100 °C
Temperature Controlling Accuracy : ± 0.1 °C
Add to compare
Catalog
Engler Viscometer LEV-B10
Graduated Flask : 200 ± 0.2 ml (50 ± 0.2 ml for bituminous materials)
Standard Water Value : 51 ± 1 s
Temperature Range : 0 ~ 100 °C
Ambient Temperature : 10 °C ~ 40 °C
Add to compare
Catalog
Foaming Characteristics Tester LFCT-A10
Temperature Range : Ambient to 100°C
Temperature Precision : ± 0.1°C
Air Flow : 94 mL ± 5 mL/min, with flowmeters
Timing Unit : 0 to 99 min 59 s, resolution 1 s
Add to compare
Catalog
Kinematics Viscometer LKV-A10
Ambient temperature : 15 to 35°C
Relative humidity : ≤ 85%
Capillary viscometer : 6 capillary Pinkevitch viscometer tubes
Stirring motor : 1200 rpm
Add to compare
Catalog
Kinematics Viscometer LKV-A11
Ambient temperature : (-10) °C ~ 35 °C
Relative humidity : ≤ 85 %
Capillary viscometer : 11 pieces
Stirring motor : 6 W, 1200 rpm
Add to compare
Catalog
Kinematics Viscometer LKV-A12
Ambient temperature : (-10) °C ~ 35 °C
Relative humidity : ≤ 85 %
Capillary viscometer : 11 pieces
Stirring motor : 6 W, 1200 rpm
Add to compare
Catalog
Kinematics Viscometer LKV-A13
Ambient temperature : (-10) °C ~ 35 °C
Relative humidity : ≤ 85 %
Capillary viscometer : 7 pieces of Cannon-Fenske reserve-flow capillary viscometer tubes in a group
Stirring motor : 6 W, 1200 rpm
Add to compare
Catalog
Low Temperature Kinematic Viscosity Tester LKV-A14
Ambient temperature : ≤ 30 °C
Relative humidity : ≤ 85 %
Capillary viscometer : 13 pieces
Stirring motor : 6 W, 1200 rpm
Add to compare
Catalog
Kinematics Viscometer LKV-A15
Ambient temperature : (-10) °C ~ 35 °C
Relative humidity : ≤ 85 %
Capillary viscometer : 11 pieces
Stirring motor : 6 W, 1200 rpm
Add to compare
Catalog
Kinematics Viscometer LKV-A16
Ambient temperature : 0 ~ 40 ºC
Relative humidity : 20 ~ 90 %, RH while 40 ℃
Temperature controlling accuracy : ± 0.1 °C
Timing range : 0.0 s ~ 9999.9 s
Add to compare
Catalog
Solidifying Point Constant Temperature Water Bath LLTT-A10
Capacity : 20 L
Temperature range : Ambient +5°C to 100°C
Precision : ± 0.1℃
Stirring range : 1200 r/min
Add to compare
Catalog
Freezing Point Tester LLTT-A11
Freezing point range : -54°C to 2°C
Cold bath measurement temperature range : -70° to 20°C
Temperature controlling accuracy : ±0.5°C
Bath liquids stirring : Electric
Add to compare
Catalog
Distillate Fuel Cold Filter Plugging Point Filter LLTT-A12
Ambient temperature : (-10)℃ ~ 35 ℃
Relative humidity : ≤ 85 %
Sample cup Inner diameter : 31.0 ~ 32.0 mm
Sample cup Wall thickness : 1.0 ~ 1.5 mm
Add to compare
Catalog
Solidifying Point Tester LLTT-A13
Temperature controlling accuracy : ± 0.5 ℃
Refrigeration system : New-type refrigeration compressor
Cold trough : Two holes in one trough, and same temperature
Ambient temperature : ≤ 30 ℃
Add to compare
Catalog
Pour and Cloud Point Tester LLTT-A14
Chamber quantity : 2 chambers
Chamber 01 temperature control : Ambient to -51 ℃
Chamber 02 temperature control : Ambient to -65 ℃
Temperature precision : ±1°C
Add to compare
Catalog
Solidifying Point and Cold Filter Plugging Point Tester LLTT-A15
Refrigeration system : New-type refrigeration compressor
Controlling temperature of cold trough : Cold trough I: RT ~ (-51) °C, ± 1°; Cold trough II:RT ~ (-80) °C, ± 1 °C
Ambient temperature : ≤ 30 ℃
Relative humidity : ≤ 85 %
Add to compare
Catalog
Multifunctional Low Temperature Tester LLTT-A16
Refrigeration system : New-type refrigeration compressor
Controlling temperature of cold trough : Cold trough I: 0 °C, ± 0.5 °C; Cold trough II: 0 °C, (-17) °C, ± 0.5 °C; Cold trough III: (-17) °C, (-34) °C, ± 0.5 °C; Cold trough IV: (-70) °C, ± 0.5 °C
Ambient temperature : ≤ 30 ℃
Relative humidity : ≤ 85 %
Add to compare
Catalog
Solidifying Point Tester LLTT-A20
Temperature controlling accuracy : ± 0.5 °C
Refrigeration system : New-type refrigeration compressor
Cold trough : One trough with two baths, temperatures in two baths are equal
Controlling temperature of cold trough : Room temperature ~ (-70) °C
Add to compare
Catalog
Solidifying Point Tester (Solidifying Point and Cold Filter Plugging Point) LLTT-A21
Refrigeration system : New-type refrigeration compressor
Cold trough : One trough with two baths, temperatures in two baths are equal
Controlling temperature of cold trough : Room temperature ~ (-70) °C
Ambient temperature : ≤ 30 ℃
Add to compare
Catalog
Solidifying Point Tester ('-20°C +80°C') LLTT-A22
Temperature controlling accuracy : ± 0.5 °C
Refrigeration system : New-type refrigeration compressor
Cold trough : One trough with two baths, temperatures in two baths are equal
Controlling temperature of cold trough : Room temperature ~ (-70) °C
Add to compare
Catalog
Automatic Pour Point Tester LLTT-A23
Ambient temperature : ≤ 30 ℃
Refrigeration speed : > 40 °C / 10 min
Repeatability for solidifying point : ≤ 2 °C
Repeatability for pour point : ≤ 3 °C
Add to compare
Catalog
Penetrometer LMPT-A10
Measurement range : 0 to 600 penetration scale
Timing controller : 5 sec, 8 sec, 10 sec, 12 sec, 30 sec and 60 sec
Time accuracy : ± 0.1 seconds
Resolution : 0.01 mm
Add to compare
Catalog
Penetrometer LMPT-A11
Measurement range : 0 to 600 penetration scale
Timing controller : 5 sec or 60 sec
Time accuracy : ± 0.1 seconds
Resolution : 0.01 mm
Add to compare
Catalog
Penetrometer LMPT-A12
Penetrometer :
Circulatory Water Bath :
Add to compare
Catalog
Penetrometer LMPT-A13
Measurement range : 0 to 600 penetration scale
Timing range : 0 sec to 60 sec
Time accuracy error : ≥ ± 0.1 seconds
Resolution : 0.1 penetration
Add to compare
Catalog
Mercaptan Sulfur Tester LMST-A10
Potential measuring range : (0 to ±1999.5) Mv
Intrinsic error : 0.1 % ±0.5 mV
Input impedance : Ri ≥1 × 1012 Ω
Burette capacity : 10 mL
Add to compare
Catalog
Octane Number and Cetane Number Tester LOCT-A10
Measuring Range For Aviation Gasoline : 86.0 to 105.0/MON
Measuring Range For Gasoline For Motor Vehicles : National standard: 65.0 to 110.0/RON
National-V standard: 70 to 115.0/RON
Blended gasoline: 75.0 to 120.0/RON
Light gasoline: 50.0 to 85.0 /MON
Isomerized gasoline: 85.0 to 120.0/RON
Arene gasoline: 90.0 to 120.0/RON
Measuring Range For Ethanol : E93: 92.0 to 95.0/RON
E97: 95.0 to 99.0/RON
Judgement: 60.0 to 120.0/RON
Measuring Range For Automobile Diesel Fuels : Cetane number: 25 to 75/CN
Cetane index: 20 to 80/CI
Add to compare
Catalog
Portable Octane Number and Cetane Meter LOCT-A20
Measurement item : motor gasoline and diesel
measurement unit of octane is ON : 40 to 120
Permissible error of octane : ± 0.5 max
Fluctuate range of octane : ± 0.2 max
Add to compare
Catalog
Open Cup Flash Point Tester LOFP-A10
Thermometer : 0 ℃ ~ 360 °C
Scale Division : 1 °C
Ambient Temperature : ≤ 35 °C
Relative Humidity : ≤ 85 %
Add to compare
Catalog
Cleveland Open Cup Flash Point Tester LOFP-A11
Thermometer : 6 ℃ ~ 400 ℃
Scale Division : 2 °C
Spout Aperture : 0.6 ~ 0.8 mm
Ambient Temperature : -10 ℃ ~ 50 ℃
Add to compare
Catalog
Automatic Cleveland Open Cup Flash Point Tester LOFP-A12
Ambient Temperature : 10 ℃ ~ 40 °C
Relative Humidity : ≤ 80 %
Temperature Measurement- Full Scale : Ambient temperature to 300 °C
Temperature Measurement- Repeatability : ≤ 8 °C
Add to compare
Catalog
Automatic COC Flash & Fire Point Tester LOFP-B10
Ambient Temperature : 10 ℃ ~ 40 ℃
Relative Humidity : ≤ 85 %
Temperature Measurement- Full Scale : Ambient temperature to ~ 400 ℃
Temperature Measurement- Repeatability : ≤ 4 ℃
Add to compare
Catalog
Automatic Lubricating Oils Oxidation Stability Tester LOST-D10
Samples : 2
Oil bath cubage : 30 L
Angle between bomb and water surface : 30 °
Speed of rotary assembly : 100 ± 5 RPM
Add to compare
Catalog
Transformer Oil Oxidation Stability Tester LOST-D11
Samples : 6
Temperature controlling mode : Automatic digital temperature
Temperature controlling range : Room temperature ~ 160 °C
Temperature controlling accuracy : ± 0.2 °C
Add to compare
Catalog
Distillate Fuel Oil Oxidation Stability Tester LOST-D12
Samples : 8
Temperature : 100 ℃
Temperature controlling accuracy : 0.1 ℃
Flow meter : 3 ± 0.3 L / H oxygen
Add to compare
Catalog
Gasoline Oxidation Stability Tester LOST-D13
Type : Compact; Desktop
Design : Integrated
Bath : Metal bath (without water usage)
Temperature control point of metal bath : 100℃ ± 1℃
Add to compare
Catalog
Oxidation Stability Tester (Lubricating Grease) LOST-D20
Temperature Range : Ambient to 150℃
Temperature Precision : ± 0.1°C
Test Unit : 2 units
Heating Power : 1800 W
Add to compare
Catalog
Liquefied Petroleum Gas Copper Corrosion Tester LRCT-A10
Sample hole : 2 pieces
Speed of stirring motor : 1400 rpm
Ambient temperature : 10 to 35°C
Temperature controlling range : Room Temperature to 100°C
Add to compare
Catalog
Lubricating Oil Rust Characteristics Tester LRCT-A11
Sample hole : 4 pieces
Speed of stirring motor : 1400 rpm
Speed for sample stirring : 1000 ± 50 rpm
Ambient temperature : Room temperature to 35°C
Add to compare
Catalog
Rust Characteristics and Corrosion Tester LRCT-A12
Sample hole : 4 pieces
Ambient temperature : Room temperature to 35°C
Temperature controlling range : 0 to 100°C
Temperature controlling accuracy : ± 1°C
Add to compare
Catalog
Copper Strip Corrosion Tester LRCT-A13
Sample hole : 4 pieces
Sample quantity : 4 to 12 pieces
Ambient temperature : Room temperature to 35 °C
Temperature controlling range : Room temperature to 100°C
Add to compare
Catalog
Carbon Residue Tester (CONRADSON METHODS) LRCT-B10
Porcelain crucible : 30 ml
Inner iron crucible : 75 ml
Outer iron crucible : 190 ml
Burner : Mig Burner
Add to compare
Catalog
Carbon Residue Tester (Digital Temperature Controlled Electric Furnace Methods) LRCT-B11
Bath type : Four holes with a furnace
Heating type : Electric resistance furnace
Temperature controlling range : 0 ~ 520 °C
Temperature controlling accuracy : ± 5 °C
Add to compare
Catalog
Carbon Residue Tester (Ramsbottom) LRCT-B20
Coking furnace : Metal furnace
Heating mode : Electric heating
Test unit : 5 units
Temperature range : Ambient to 550°C
Add to compare
Catalog
Rotational Viscometer LRV-A10
Viscosity measurement range : 10 ~ 2000000 MPa•s
Ambient temperature : 5 °C ~ 35 °C
Ambient humidity : Not more than 80 %
Spindles : Four spindles of No.1 ~ 4
Add to compare
Catalog
Specific Gravity Tester LSGT-A10
Vessel Volume : 4000 ml × 2
Power of Vacuum pump : 160 W
Negative power : 3.7 kPa(27.75 mmHg)
Power of shaking machine : 30 W
Add to compare
Catalog
Automatic Softening Point Tester LSPT-A10
Measurement range : 32 ℃ to 160 ℃
Ambient temperature : 35 °C
Temperature resolution : 0.01 ℃
Beaker volume : 1000 mL
Add to compare
Catalog
X-ray Fluorescence Sulfur in Oil Analyzer LST-A10
Sample quantity : 2 to 3 ml (it is equal to sample depth of 3 mm to 4 mm)
Measurement time : 60, 120, 240, 300, and 600 s at random
Measurement range : 7 ppm to 5 %
Repeatability : < 0.029 (S + 0.6)
Add to compare
Catalog
Dark Petroleum Products Sulphur Content Tester (Tubular Oven Method) LST-A11
Air flow rate : Not less than 150 L / h
Max. Preset time : 99 min 59 s (100 min)
Chamber diameter of oven : Φ22 mm
Heating power of oven : 1400 W × 2
Add to compare
Catalog
Automatic Thermogravimetric Analyzer LTGA-A10
Temperature range : Room temperature to 1000 ºC
Temperature resolution : 0.1 ºC
Temperature fluctuation : ±0.1 ºC
Heating rate : 1 ~ 80 ºC / min
Add to compare
Catalog
Constant Temperature Needle Penetration Tester LTNP-A10
Measuring range : 0 to 700 taper degree (digital display table 0-70 mm)
Timing device : Timing error is less than ±0.1 s
Resolution : 0.01 mm
Needle insertion accuracy : ±1 cone insertion degree
Add to compare
Catalog
Vapor Pressure Tester (REID METHOD) LVPT-C10
Operation temperature of water bath : RT ~ 90 °C
Temperature controlling accuracy : ± 0.1 °C
Dimensions : 550 × 520 × 102 mm
Pressure meter accuracy : ± 0.4 % kPa
Add to compare
Catalog
Petroleum Products Vapor Pressure Tester(REID METHODS) LVPT-C11
Test bomb : Two samples or a group of parallel samples
Bath temperature : 37.8 °C
Temperature controlling accuracy : 0.1 °C
Dimensions : 500 × 560 × 680 mm, 950 × 540 × 720 mm
Add to compare
Catalog
Water Content Tester LWT-A10
Ambient Temperature : ≤ 35 °C
Relative Humidity : ≤ 85 %
Heating Power of Electric Furnace : 1000 W
Sample Determination : 1 at once
Add to compare
Catalog
Water Content Tester LWT-A11
Ambient Temperature : ≤ 35 °C
Relative Humidity : ≤85 %
Heating Power of Electric Furnace : 1000 W × 2
Sample Determination : 2 at once
Add to compare
Catalog
Coulometric Karl Fischer Titrator LWT-A30
Ambient Temperature : 10°C to 35°C
Measurement Range : 0 to 100 mg
Resolution : 0.1 µg
Max. Electrolysis Speed : 40 µg /s
Add to compare
Catalog
Coulometric Karl Fischer Titrator LWT-A31
Maximum current : 400 mA
Measurement range : 3 µg to 9999.9 µg
Resolution : 0.1 µg
Precision 1 : ± 2 µg (3µg H
2
O to 20µg H
2
O)
Add to compare
Catalog
Crude Petroleum Water Content Tester LWT-B10
Ambient Temperature : (-10) °C ~ 35 °C
Relative Humidity : ≤ 85 %
Distillation flask : 1000 ml
Water receiver : 5 ml
Add to compare
Catalog
COMPARE
Popular Products
Amino Acid Analyzer
Autoclaves
Baths and Circulators
Cabinets
Centrifuge
Freezers
Freeze Dryers
Fume Hood
Muffle Furnace
Tube Furnace
Ice Makers
Incubator
Kjeldahl Systems
Laboratory Shakers and Mixers
Oven
Peristaltic Pump
Refrigerators
More...
Navigation
Home
Products
Catalogs
About us
Contact Us
Connect with us
Facebook
Twitter
Pinterest
Quora
Google+
Contact Us Map