Atomic Fluorescence Spectrometer LAFS-A10 is a microprocessor controlled double-channel, non-dispersive unit used for trace element composition, ultra-trace analysis of Mercury and all other hydride-forming elements. Pre adjusted referral optical plane to coincide atomizer center with optical focus. Equipped with a feature of real time conversion of data into graph.

Beam ConfigurationDual Channel
Elements ( Measuring Range )
As, Se, Pb, Bi, Sb, Te, Sn< 0.01 µg/L
Hg, Cd< 0.001 µg/L
Zn< 1.0 µg/L
Ge< 0.1 µg/L
Precision ( RSD )< 1.0
Linear rangeMore than 3 orders of magnitude
LampHollow cathode lamp
Power Supply220 V
Dimension1000 x 350 x 390 mm
Weight70 Kg
  • Double channel detection for trace element analysis
  • Peak height and peak area integral detection method
  • High stability light source
  • High intensity hollow cathode lamps for high sensitivity and stability
  • Gas - liquid separator for improved repeatability of results
  • Double shielded quartz atomizer with automatic igniting argon – hydrogen flame
  • Stable gas flow
  • Automatic gas alarm pressure at critical point
  • USB communication for real time automatic detection
Used in analysis / detection of compound present in air of water, heavy metal detection, redirect photons , in various fields of geology, metallurgy, medicine, chemical industry, food inspection, water supply, waste water treatment and scientific research.

ICP Spectrometer

ICP Spectrometer : ICP spectrometer LICP-A10

ICP spectrometer LICP-A10

  • Wavelength range ( 3600 lines / mm )
  • 180 to 500 nm
  • Wavelength range ( 2400 lines / mm )
  • 180 to 800 nm
  • Temperature
  • 20 ~ 28 °C
ICP Spectrometer : ICP Spectrometer LICP-A11

ICP Spectrometer LICP-A11

  • Wavelength range
  • 180 to 900 nm
  • Elements per minute
  • 15 elements
  • Temperature
  • 29 °C
ICP Spectrometer : ICP Spectrometer LICP-B10
ICP Spectrometer LICP-B10
  • Monochromator Specifications
  • Czerny turner
  • Solid State Power Specifications
  • 27.12 MHz Frequency stability: < 0.05%
  • Technical Specifications
  • Liquid sample: 0.01 ppm to several thousand ppm Solid or power sample: 0.001% to 70%

XRF Spectrometer

XRF Spectrometer : XRF-Spectrometer LXRF-A10

XRF-Spectrometer LXRF-A10

  • Measureable elements
  • S to U
  • Detection limit
  • 1 ppm
  • Temperature
  • 15 ~ 30 °C
XRF Spectrometer : Handheld XRF Spectrometer LXRF-B10

Handheld XRF Spectrometer LXRF-B10

  • Analytical Method
  • Energy dispersive X-ray fluorescence analytical Method
  • Elements Measuring
  • Atomic number from 12 to 92 [elements from magnesium (Mg) to uranium (U)] can be measured
  • Range
  • Simultaneous detector
XRF Spectrometer : Handheld XRF Spectrometer LXRF-B11
Handheld XRF Spectrometer LXRF-B11
  • Analytical Method
  • Energy dispersive X-ray fluorescence analytical Method
  • Elements Measuring
  • Atomic number from 12 to 92 [elements from magnesium (Mg) to uranium (U)] can be measured
  • Range
  • Simultaneous detector