Download Catalog for Nucleic Acid Purification System LNAP-A21

Nucleic Acid Purification System LNAP-A21

Nucleic Acid Purification System LNAP-A21

www.labtron.co.uk | info@labtron.co.uk

Overview

Nucleic Acid Purification System LNAP-A21 adopts magnetic bead separation technology with consumable of 5 ml tube strip and magnetic rod’s tip. Integrated with program management includes PC software, APP software, program editing, setting and management procedures. It is a benchtop unit comes with sample quantity of 10 and process volume ranges from 50 to 1000 µl. Offers elution temperature ranges from ambient temperature to 120°C and lysis temperature ranges from ambient temperature to 120°C. Built-in exhaust fan, lighting LED lights to observe running status of the instrument in real time and 4.3 inch touch screen display.

Specifications :
Maximum Sample Volume 5 ml
Sample Quantity 10
Process Volume 50 to 1000 µl
Consumable 5 ml tube strip+ Magnetic rod’s tip
Throughput 1 to 10
Block Heating Yes (RT + 5°C to 105°C)
Lysis Temperature Ambient temperature to 120°C
Elution Temperature Ambient temperature to 120°C
Purification Accuracy 100 Copy sample positive rate > 95 %
Stability CV < 5 %
Collection Efficiency > 95 %
Mixing Mixing methods is editable according to different requirements
Operation Interface 4.3 inch touch screen, 3 shortcut keys, external mouse
Built-in Protocol Pre-set 6 group programs, 100 pcs program can be saved
Program Management PC software, APP software, Program editing, Easier management
Extension Interface Standard USB, LAN, Wi-Fi
Lighting Yes
Pollution Control UV light
Exhaust Way By Fan
Data Storage Built-in SD card
Maximum Input Power 350 W
Dimension 340×350×410 mm
Weight 18.5 kg
Features :
  • -  High yield of nucleic acid with low magnetic bead loss and good repeatability of results
  • -  Large guide rail design offers more reliable structure and Screw rod design provide high operating accuracy
  • -  4.3 inch touch screen display for ease of monitoring various parameters
  • -  Space saving design with maximum sample volume of 5 ml
  • -  10 samples can be processed at a same time
  • -  Avoid cross contamination and provide UV disinfection
  • -  Integrated with elution, lysis and heating function
  • -  Manual setting of open instrument parameters
  • -  APP software (Android system) which can monitor the system in real time through mobile device
  • -  Built in with function such as QR code identification, magnetic absorption and release, mixing speed, cooling fan and other function
Labtron