Double Beam UV-Vis Spectrophotometer LUS-B20 is a double beam designed UV-Vis spectrophotometer, offers 190 to 1100 nm of wavelength range with C-T monochromator and 1600 L/mm holographic grating. Features 3D spectrogram measurement for sample with dynamic change, this spectrophotometer has adjustable spectral bandwidth of 1.0 nm to 5.0 nm. Designed compactly with fixed 2 trench sample holder, deuterium and tungsten lamp as light source, it has automatic calibration. Equipped with photomultiplier sensor, digital signal and USB interface, 4 quartz cuvette, this spectrophotometer provides high resolution, low stray light, lasting stability, and powerful software function.

Wavelength range190 to 1100 nm
Spectral bandwidth1.0 to 5.0 nm (adjustable)
Optical systemDouble beam, C-T monochromator, 1600 L/mm holographic grating
Wavelength accuracy±0.3 nm
Wavelength repeatability0.1 nm
Wavelength resolution0.05 nm
Wavelength edge noise100%T line ≤0.1%T;0%T line ≤0.05%T
Stray light0.015 %T (at 220nm and 360 nm)
Baseline flatness≤±0.001 Abs
Baseline noise±0.1 %T
Baseline drift≤0.0004 Abs / h (after warm-up at 500 nm)
Standard sample holderFixed 2 trench sample holder
Measuring length0 to 200% T, -4.000 to 4.000 Abs, -9999 to 9999C, -9999 to 9999F
Transmittance accuracy±0.3 %T
Transmittance repeatability0.1 % T
Light switching pointAdjustable; 294 nm to 365 nm
Light SourceDeuterium lamp, Tungsten lamp (20 W/12 V)
DetectorSilicon photodiode detector
InterfaceDigital signal; USB
Cuvette4 quartz cuvette; 10 mm optical path
Power supply220 V ± 10%, 50Hz
Power200 W
Dimension (L×W×H)620×510×245 mm
Package dimension (L×W×H)745×635×400 mm
Net weight30 kg
Gross weight39 kg
  • Double beam designed UV-Vis spectrophotometer
  • 190 to 1100 nm of wavelength range with 1600 L/mm holographic grating
  • 3D spectrogram measurement for sample with dynamic change
  • Adjustable spectral bandwidth of 1.0 nm to 5.0 nm
  • Fixed 2 trench sample holder, deuterium and tungsten lamp as light source
  • Photomultiplier sensor, digital signal and USB interface
  • 4 quartz cuvette of 10 mm optical path
  • PC control software (Windows based)
  • Automatic calibration
  • Highly stable, User-friendly, Controlled by PC
Double Beam UV-Vis Spectrophotometer is used for photometric measurement, spectrum scan, quantitative determination, dynamics measurement, 3D map measurement, multi-wavelength test, DNA/ Protein concentration measurement etc. across factories, schools, metallurgy, agriculture, food industry, biochemistry, environment protection, petrochemical industry, medical and health and scientific research institutes or labs etc.

Double Beam UV/Vis Spectrophotometer

Our range of Double Beam UV/VIS spectrophotometers offer long optical path which ensure high accuracy and stability. Its design measures the transmittance of the sample and solvent simultaneously. It is highly precise and performs powerful analysis.

Double Beam UV/Vis Spectrophotometer : Double Beam UV/Vis Spectrophotometer LUS-B16

Double Beam UV/Vis Spectrophotometer LUS-B16

  • Wavelength Range
  • 190 ~ 1100 nm
  • Setting Wavelength
  • Automatic
  • Spectral Bandwidth
  • 0.5 / 1.0 / 2.0 / 4.0 nm adjustable
Double Beam UV/Vis Spectrophotometer : Double beam UV-Visible Spectrophotometer LUS-B14

Double beam UV-Visible Spectrophotometer LUS-B14

  • Wavelength range
  • 190 ~ 1100 nm
  • Spectral bandwidth
  • 1.8 nm
  • Wavelength accuracy
  • ± 0.3 nm
Double Beam UV/Vis Spectrophotometer : Double Beam UV/Vis Spectrophotometer LUS-B30
Double Beam UV/Vis Spectrophotometer LUS-B30
  • Wavelength range
  • 190 to 1100 nm
  • Spectral bandwidth
  • 2 nm
  • Wavelength Accuracy
  • ± 0.1nm @ 656.1 nm, ± 0.3 nm @ all
Double Beam UV/Vis Spectrophotometer : Double Beam UV/Vis Spectrophotometer LUS-B31
Double Beam UV/Vis Spectrophotometer LUS-B31
  • Wavelength range
  • 190 to 1100 nm
  • Spectral bandwidth
  • 1 nm
  • Wavelength Accuracy
  • ± 0.1nm @ 656.1 nm, ± 0.3 nm @ all

Nano Spectrophotometer

We produce a wide range of Nano spectrophotometer for qualitative and quantitative analysis of DNA/RNA in the sample. Our product is highly sensitive and requires only 0.5-2µl of sample for analysis.

Nano Spectrophotometer : Nano Spectrophotometer LNS-A10

Nano Spectrophotometer LNS-A10

  • Wavelength range
  • 200 - 800 nm
  • Path length
  • 0.2 mm (For high concentration measurement); 1.0 mm (For ordinary)
  • Wavelength accuracy
  • ± 1 nm
Nano Spectrophotometer : Nano Spectrophotometer LNS-A21

Nano Spectrophotometer LNS-A21

  • Wavelength range
  • 200 - 850 nm
  • Path length
  • 1 mm, 2 mm, 5 mm, 10 mm
  • Wavelength accuracy
  • ± 1 nm
Nano Spectrophotometer : Nano Spectrophotometer LNS-B11
Nano Spectrophotometer LNS-B11
  • Wavelength range
  • 230 nm, 260 nm, 280 nm
  • Path length
  • 1.0 mm, 0.2 mm
  • Minimum Sample size
  • 0.3 - 2.0 µl
Nano Spectrophotometer : Nano Spectrophotometer LNS-C10
Nano Spectrophotometer LNS-C10
  • Cuvette
  • No
  • PC
  • Inbuilt
  • Wavelength range
  • 190 - 850 nm

Single Beam UV/Visible Spectrophotometer

We manufacture highly precise UV/Vis automatic scanning spectrophotometer with wavelength ranging from 190-1100nm. It can perform quantitative measurement, photometric measurement, spectrum scanning, DNA/Protein analysis. It is in demand for its user-friendly operations

Single Beam UV/Visible Spectrophotometer : Single Beam UV/Visible Spectrophotometer LUS-A10

Single Beam UV/Visible Spectrophotometer LUS-A10

  • Wavelength Range
  • 190 ~ 1100 nm
  • Spectral Bandwidth
  • 1 nm
  • Wavelength Accuracy
  • ± 0.3 nm
Single Beam UV/Visible Spectrophotometer : Single Beam UV/Visible Spectrophotometer LUS-A11

Single Beam UV/Visible Spectrophotometer LUS-A11

  • Wavelength Range
  • 190 ~ 1100 nm
  • Spectral Bandwidth
  • 1.8 nm
  • Wavelength Accuracy
  • ± 0.3 nm
Single Beam UV/Visible Spectrophotometer : Single Beam UV/Visible Spectrophotometer LUS-A20
Single Beam UV/Visible Spectrophotometer LUS-A20
  • Wavelength Range
  • 190 ~ 1100 nm
  • Setting Wavelength
  • Automatic
  • Spectral Bandwidth
  • 2 nm
Single Beam UV/Visible Spectrophotometer : Single Beam UV/Visible Spectrophotometer LUS-A21
Single Beam UV/Visible Spectrophotometer LUS-A21
  • Wavelength Range
  • 190 ~ 1100 nm
  • Setting Wavelength
  • Automatic
  • Spectral Bandwidth
  • 1.8 nm

Visible Spectrophotometer

Labtron provides extensive range of visible spectrophotometer LVS series which can operate over a wavelength range of 320-1100nm. It brings unmatched performance with outstanding accuracy and precision.

Visible Spectrophotometer : Vis Spectrophotometer LVS-A10

Vis Spectrophotometer LVS-A10

  • Wavelength Range
  • 330 to 1000 nm
  • Spectral Bandwidth
  • 5 nm
  • Wavelength Accuracy
  • ± 2 nm
Visible Spectrophotometer : Vis Spectrophotometer LVS-A11

Vis Spectrophotometer LVS-A11

  • Wavelength Range
  • 335 ~ 1000 nm
  • Spectral Bandwidth
  • 4 nm
  • Wavelength Accuracy
  • ± 2 nm
Visible Spectrophotometer : Vis Spectrophotometer LVS-B10
Vis Spectrophotometer LVS-B10
  • Wavelength Range
  • 325 ~ 1000 nm
  • Setting Wavelength
  • Automatic
  • Spectral Bandwidth
  • 2 nm
Visible Spectrophotometer : Vis Spectrophotometer LVS-C10
Vis Spectrophotometer LVS-C10
  • Wavelength Range
  • 320 ~ 1100 nm
  • Spectral Bandwidth
  • 4 nm
  • Wavelength Accuracy
  • ± 0.5 nm

Atomic Absorption Spectrophotometer

Labtron Atomic Absorption Spectrophotometer makes use of the modern in technology. It is acquired after thorough research into the desires of the diagnostic community. It has all the power, performance and speed necessitated in today’s modern laboratory.

Atomic Absorption Spectrophotometer : Atomic Absorption Spectrophotometer LAAS-A11

Atomic Absorption Spectrophotometer LAAS-A11

  • Wavelength range
  • 190 - 900 nm
  • Spectral Bandwidth
  • 0.2 nm, 0.4 nm, 0.7 nm, 1.4 nm, 2.4 nm, 5.0 nm
  • Wavelength accuracy
  • ≤ ± 0.5 nm
Atomic Absorption Spectrophotometer : Atomic Absorption Spectrophotometer LAAS-A20

Atomic Absorption Spectrophotometer LAAS-A20

  • Wavelength range
  • 180 - 900 nm
  • Spectral Bandwidth
  • 0, 0.2, 0.4, 1.0, 2.0nm (Automatic setting)
  • Wavelength accuracy
  • ≤ 0.15 nm
Atomic Absorption Spectrophotometer : Atomic Absorption Spectrophotometer LAAS-A21
Atomic Absorption Spectrophotometer LAAS-A21
  • Wavelength range
  • 180 – 900 nm
  • Spectral Bandwidth
  • 0 nm, 0.2 nm, 0.4 nm, 1.0 nm, 2.0 nm (5 steps with automatic changeover)
  • Wavelength accuracy
  • ≤ 0.15 nm
Atomic Absorption Spectrophotometer : Atomic Absorption Spectrophotometer LAAS-A22
Atomic Absorption Spectrophotometer LAAS-A22
  • Wavelength range
  • 180 – 900 nm
  • Spectral Bandwidth
  • 0.1 nm,0.2 nm,0.4 nm, 1.0 nm, 2.0 nm automatic setting
  • Wavelength accuracy
  • ≤ 0.15 nm

Table Top Spectrophotometer

Table Top Spectrophotometer : Table top spectrophotometer LTS-A10

Table top spectrophotometer LTS-A10

  • Illumination system
  • d/8 (Diffused lighting, 8° observation angle) SCS optical engine (light splitting and integration system) ETC (real time calibration technology ) SCI (specular reflection included) & SCE(specular reflection excluded) simultaneous measurement
  • Size of integrated sphere
  • 40 mm, alvan diffused reflection surface coating
  • Illumination light source
  • CLED
Table Top Spectrophotometer : Table top spectrophotometer LTS-A11

Table top spectrophotometer LTS-A11

  • Illumination system
  • d/8 (Diffused lighting, 8° observation angle) SCS optical engine (light splitting and integration system) ETC (real time calibration technology ) SCI (specular reflection included) & SCE(specular reflection excluded) simultaneous measurement
  • Size of integrated sphere
  • 40 mm, alvan diffused reflection surface coating
  • Illumination light source
  • CLED
Table Top Spectrophotometer : Table top spectrophotometer LTS-A12
Table top spectrophotometer LTS-A12
  • Illumination system
  • d/8 (Diffused lighting, 8° observation angle) SCS optical engine (light splitting and integration system) ETC (real time calibration technology ) SCI (specular reflection included) & SCE(specular reflection excluded) simultaneous measurement
  • Size of integrated sphere
  • 15.2 cm, alvan diffused reflection surface coating
  • Illumination light source
  • CLED
Table Top Spectrophotometer : Table top spectrophotometer LTS-A13
Table top spectrophotometer LTS-A13
  • Illumination system
  • d/0 (Diffused lighting, 0° observation viewing), SCS optical engine (light splitting and integration system), ETC (every time calibration technology), SCI (specular reflection included)/ SCE (specular reflection excluded) simultaneous measurement
  • Size of integrated sphere
  • 40 mm, alvan diffused reflection surface coating
  • Illumination light source
  • CLED

Portable Spectrophotometer

Portable Spectrophotometer : Portable spectrophotometer LSP-A10

Portable spectrophotometer LSP-A10

  • Illumination
  • d/8 (Diffused lighting, 8° observation angle) SCS optical engine (light splitting and integration system) ETC (real time calibration technology ) SCI (specular reflection included) & SCE(specular reflection excluded) simultaneous measurement
  • Repeatability
  • Light splitting reflectivity:standard deviation within 0.08% Color values:ΔE*ab
  • Sensor
  • Blue light enhanced sensor array
Portable Spectrophotometer : Portable spectrophotometer LSP-A11

Portable spectrophotometer LSP-A11

  • Illumination
  • d/8 (Diffused lighting, 8° observation angle) SCS optical engine (light splitting and integration system) ETC (real time calibration technology ) SCI (specular reflection included) & SCE(specular reflection excluded) simultaneous measurement
  • Repeatability
  • Light splitting reflectivity:standard deviation within 0.08% Color values:ΔE*ab Maximum:0.03
  • Sensor
  • Dual light path sensor array
Portable Spectrophotometer : Portable spectrophotometer LSP-A12
Portable spectrophotometer LSP-A12
  • Illumination
  • d/8 (Diffused lighting, 8° observation angle) SCS optical engine (light splitting and integration system) ETC (real time calibration technology ) SCI (specular reflection included) & SCE(specular reflection excluded) simultaneous measurement
  • Repeatability
  • Light splitting reflectivity:standard deviation within 0.08% Color values:ΔE*ab
  • Sensor
  • Photoelectric diode sensor
Portable Spectrophotometer : Portable spectrophotometer LSP-A13
Portable spectrophotometer LSP-A13
  • Illumination
  • d/8 (Diffused lighting, 8° observation angle) SCS optical engine (light splitting and integration system) ETC (real time calibration technology ) SCI (specular reflection included) & SCE(specular reflection excluded) simultaneous measurement
  • Repeatability
  • Light splitting reflectivity:standard deviation within 0.08% Color values:ΔE*ab
  • Sensor
  • Photoelectric diode sensor

Fluorescence Spectrophotometer

Fluorescence Spectrophotometer : Fluorescence Spectrophotometer LFS-A10

Fluorescence Spectrophotometer LFS-A10

  • Light source
  • 150 W Xenon lamp
  • Excitation wavelength
  • 200 nm to 900 nm
  • Emission wavelength
  • 200 nm to 900 nm
Fluorescence Spectrophotometer : Fluorescence Spectrophotometer LFS-A12

Fluorescence Spectrophotometer LFS-A12

  • Light source
  • 150 W Xenon lamp
  • Excitation wavelength
  • 200 nm to 900 nm
  • Emission wavelength
  • 200 nm to 900 nm
Fluorescence Spectrophotometer : Fluorescence Spectrophotometer LFS-A11
Fluorescence Spectrophotometer LFS-A11
  • Excitation Source
  • 150 W Xenon Lamp
  • Excitation Wavelength
  • 200 nm to 900 nm
  • Excitation Slit
  • 1 nm, 2 nm, 5 nm, 10 nm, 20 nm

Xenon Lamp Spectrophotometer

Xenon Lamp Spectrophotometer : Xenon Lamp Spectrophotometer LXLS-A10

Xenon Lamp Spectrophotometer LXLS-A10

  • Optical system
  • Double Beam, Grating 1200 lines/mm
  • Wavelength Range
  • 190 nm to 1100 nm
  • Spectral Bandwidth
  • 2 nm
Xenon Lamp Spectrophotometer : Xenon Lamp Spectrophotometer LXLS-A11

Xenon Lamp Spectrophotometer LXLS-A11

  • Optical system
  • Double Beam, Grating 1200 lines/mm
  • Wavelength Range
  • 190 nm to 1100 nm
  • Spectral Bandwidth
  • 1 nm
Xenon Lamp Spectrophotometer : Xenon Lamp Spectrophotometer LXLS-A13
Xenon Lamp Spectrophotometer LXLS-A13
  • Optical system
  • Double Beam, Grating 1200 lines/mm
  • Wavelength Range
  • 190 nm to 1100 nm
  • Spectral Bandwidth
  • 2 nm
Xenon Lamp Spectrophotometer : Xenon Lamp Spectrophotometer LXLS-A14
Xenon Lamp Spectrophotometer LXLS-A14
  • Optical system
  • Double Beam, Grating 1200 lines/mm
  • Wavelength Range
  • 190 nm to 1100 nm
  • Spectral Bandwidth
  • 1 nm