Flame Atomic Absorption Spectrophotometer LAAS-A13 is a microprocessor controlled instrument based on analysis of metal ions by flame and graphite furnace atomizer with their absorption at wavelength of 190 to 900 nm. Czerny-Turner monochromator and variance of bandwidth provides user flexibility. It is provided with deuterium hollow cathode lamp to exclude interference of molecular absorption and Titanium Burner to increase the analysis efficiency and precision of flame. Its double beam radiation sources enables good basic line stability. Graphic analysis system provides data on analysis of entire process e.g. measured value, temperature, procedures, time, etc. It has great applications in research, medicine, environmental science and other industries.

Working spectral range 190 to 900 nm
Spectral Bandwith 0.1, 0.2, 0.4, 1.0 and 2.0 nm
Wavelength accuracy ± 0.15 nm
Wavelength repeatability ≤ 0.04 nm
Baseline stability ≤ 0.002 Abs / 30 min
Characteristic concentration of copper 0.02 μg / ml / 1 %
Detection limit of copper 0.004 μg / ml
Measurement Repeatability 0.005
Grating 1800 lines / mm
Inflamer All-metal titanium burner
Atomizer Efficient glass atomizer
Lamp stand 8 lamps automatic turret, automatic alignment
D2 Background calibration ability 1 A ≤ 30 times correction ability
Dimensions 700 × 550 × 450 mm
Net weight 75 Kg
Power supply 220 V ± 22 V AC
Acetylene air burner 100 mm
Ignition dynamic baseline drift ≤ 0.006 Abs / 30 min
Characteristic viscocity ≤ 0.025 μg / ml / 1 %
Standard deviation of the accuracy ≤ 0.5 % (Cu, absorbance > 0.8 A) (detection limit Cu ≤ 0.008 μg / ml)
Protection system Can inevitably cut off gas if pressure is low, power cut-off, flame out and alteration of the burner
  • Integrated flame/graphite furnace atomization system, changeable with flame emission burner
  • Turret for 8 pre-aligned Hollow Cathode Lamps fitted with pre-heating, and individual pre-centred lamps
  • PID and Dual curve mode light-controlled temperature control technique ensures fast heating and analytical sensitivity
  • Fully automated wavelength scanning and peak searching
  • Advance software for complete parameter settings
  • Reliable fully automatic graphite furnace analysis
  • Alarm feature to protect fuel gas leakage, abnormal flow, insufficient air pressure and abnormal flame extinction in flame system
  • Analysis of elements by flame absorption method and emission method
  • Strong database system which possesses more than 500 data self-storage
  • Results printed as parameter, data result and diagram
It is suitable to analyse trace amount of element from mixture, also in forensics and chemistry, biological science to detect toxic elements from blood and drug samples.

Atomic Absorption Spectrophotometer

Labtron Atomic Absorption Spectrophotometer makes use of the modern in technology. It is acquired after thorough research into the desires of the diagnostic community. It has all the power, performance and speed necessitated in today’s modern laboratory.

Atomic Absorption Spectrophotometer LAAS-A22

Atomic Absorption Spectrophotometer LAAS-A22

  • Wavelength range
  • 180 – 900 nm
  • Spectral Bandwidth
  • 0.1 nm,0.2 nm,0.4 nm, 1.0 nm, 2.0 nm automatic setting
  • Wavelength accuracy
  • ≤ 0.15 nm
Atomic Absorption Spectrophotometer LAAS-A21

Atomic Absorption Spectrophotometer LAAS-A21

  • Wavelength range
  • 180 – 900 nm
  • Spectral Bandwidth
  • 0 nm, 0.2 nm, 0.4 nm, 1.0 nm, 2.0 nm (5 steps with automatic changeover)
  • Wavelength accuracy
  • ≤ 0.15 nm
Atomic Absorption Spectrophotometer LAAS-A20

Atomic Absorption Spectrophotometer LAAS-A20

  • Wavelength range
  • 180 - 900 nm
  • Spectral Bandwidth
  • 0, 0.2, 0.4, 1.0, 2.0nm (Automatic setting)
  • Wavelength accuracy
  • ≤ 0.15 nm
Atomic Absorption Spectrophotometer LAAS-A11

Atomic Absorption Spectrophotometer LAAS-A11

  • Wavelength range
  • 190 - 900 nm
  • Spectral Bandwidth
  • 0.2 nm, 0.4 nm, 0.7 nm, 1.4 nm, 2.4 nm, 5.0 nm
  • Wavelength accuracy
  • ≤ ± 0.5 nm

Double Beam UV/Vis Spectrophotometer

Our range of Double Beam UV/VIS spectrophotometers offer long optical path which ensure high accuracy and stability. Its design measures the transmittance of the sample and solvent simultaneously. It is highly precise and performs powerful analysis.

Double Beam UV-Vis Spectrophotometer LUS-B10

Double Beam UV-Vis Spectrophotometer LUS-B10

  • Wavelength Range
  • 190 to 1100 nm
  • Spectral Bandwidth
  • 1.8 nm
  • Optical System
  • Double beam
Double Beam UV-Vis Spectrophotometer LUS-B13

Double Beam UV-Vis Spectrophotometer LUS-B13

  • Wavelength Range
  • 190 to 1100 nm
  • Spectral Bandwidth
  • 1.0 nm
  • Optical System
  • Double beam
Double Beam UV-Vis Spectrophotometer LUS-B12

Double Beam UV-Vis Spectrophotometer LUS-B12

  • Wavelength Range
  • 190 to 1100 nm
  • Spectral Bandwidth
  • 1.8 nm
  • Optical System
  • Split double beam, C-T monochromator,1200 L/mm holographic grating
Double Beam UV/Vis Spectrophotometer LUS-B30

Double Beam UV/Vis Spectrophotometer LUS-B30

  • Wavelength range
  • 190 to 1100 nm
  • Spectral bandwidth
  • 2 nm
  • Wavelength Accuracy
  • ± 0.1nm @ 656.1 nm, ± 0.3 nm @ all

Nano Spectrophotometer

We produce a wide range of Nano spectrophotometer for qualitative and quantitative analysis of DNA/RNA in the sample. Our product is highly sensitive and requires only 0.5-2µl of sample for analysis.

Nano Spectrophotometer LNS-A20

Nano Spectrophotometer LNS-A20

  • Wavelength range
  • 190 to 850 nm
  • Wavelength accuracy
  • ± 1 nm
  • Wavelength Resolution
  • 2 nm (FWHM at Hg 546 nm)
Nano Spectrophotometer LNS-C11

Nano Spectrophotometer LNS-C11

  • Cuvette
  • Yes
  • PC
  • Inbuilt
  • Wavelength range
  • 190 - 850 nm
Nano Spectrophotometer LNS-B20

Nano Spectrophotometer LNS-B20

  • Wavelength Range
  • 200 to 800 nm
  • Sample Size
  • 0.5 to 2.0 µl
  • Path length
  • 0.05 mm 0.2 mm 1.0 mm
Nano Spectrophotometer LNS-B10

Nano Spectrophotometer LNS-B10

  • Wavelength
  • 260 nm and 280 nm; Fixed
  • Spectral resolution
  • ≤ 8 nm
  • Path length
  • 0.5 mm

Single Beam UV/Visible Spectrophotometer

We manufacture highly precise UV/Vis automatic scanning spectrophotometer with wavelength ranging from 190-1100nm. It can perform quantitative measurement, photometric measurement, spectrum scanning, DNA/Protein analysis. It is in demand for its user-friendly operations

Single Beam UV/Visible Spectrophotometer LUS-A21

Single Beam UV/Visible Spectrophotometer LUS-A21

  • Wavelength Range
  • 190 ~ 1100 nm
  • Setting Wavelength
  • Automatic
  • Spectral Bandwidth
  • 1.8 nm
Single Beam UV/Visible Spectrophotometer LUS-A40

Single Beam UV/Visible Spectrophotometer LUS-A40

  • Wavelength Range
  • 190 ~ 1100 nm
  • Spectral Bandwidth
  • 0.5 / 1.0 / 2.0 / 4.0 / 5.0 nm
  • Wavelength Accuracy
  • ± 0.3 nm
Single Beam UV-Vis Spectrophotometer LUS-C10

Single Beam UV-Vis Spectrophotometer LUS-C10

  • Wavelength Range
  • 200 to 1000 nm
  • Spectral Bandwidth
  • 4.0 nm
  • Optical System
  • Single beam
Single Beam UV/Visible Spectrophotometer LUS-A30

Single Beam UV/Visible Spectrophotometer LUS-A30

  • Wavelength Range
  • 190 ~ 1100 nm
  • Setting Wavelength
  • Automatic
  • Spectral Bandwidth
  • 4 nm

Visible Spectrophotometer

Labtron provides extensive range of visible spectrophotometer LVS series which can operate over a wavelength range of 320-1100nm. It brings unmatched performance with outstanding accuracy and precision.

Vis Spectrophotometer LVS-C11

Vis Spectrophotometer LVS-C11

  • Wavelength Range
  • 320 ~ 1000 nm
  • Spectral Bandwidth
  • 2 nm
  • Wavelength Accuracy
  • ± 0.5 nm
Vis Spectrophotometer LVS-A10

Vis Spectrophotometer LVS-A10

  • Wavelength Range
  • 330 to 1000 nm
  • Spectral Bandwidth
  • 5 nm
  • Wavelength Accuracy
  • ± 2 nm
Visible Spectrophotometer LVS-A21

Visible Spectrophotometer LVS-A21

  • Photometry
  • Single Beam
  • Monochromatic Type
  • Czerny-Turner
  • Wavelength range
  • 325 to 1000nm
Vis Spectrophotometer LVS-C10

Vis Spectrophotometer LVS-C10

  • Wavelength Range
  • 320 ~ 1100 nm
  • Spectral Bandwidth
  • 4 nm
  • Wavelength Accuracy
  • ± 0.5 nm