Octane Number and Cetane Number Tester LOCT-A10 is benchtop unit designed to measure Motor octane number (MON) of aviation gasoline, light gasoline; Research octane number (RON) of gasoline for motor vehicles, blended gasoline, isomerised gasoline, arene gasoline, ethanol and Cetane number of automobile diesel fuel. Test results meets the standards of ASTM D2699-86 and ASTM D613 - 18a. Features like digital transmission technology, anti-jamming, accurate results after several repetitions, less sample volume, short test time, LCD display etc. makes it highly reliable. It is widely used in testing labs, petroleum industry, quality control, etc.

 Measuring Range For Aviation Gasoline 86.0 to 105.0/MON
 Measuring Range For Gasoline For Motor Vehicles National standard: 65.0 to 110.0/RON<br/> National-V standard: 70 to 115.0/RON<br/> Blended gasoline: 75.0 to 120.0/RON<br/> Light gasoline: 50.0 to 85.0 /MON<br/> Isomerized gasoline: 85.0 to 120.0/RON<br/> Arene gasoline: 90.0 to 120.0/RON
 Measuring Range For Ethanol E93: 92.0 to 95.0/RON<br/> E97: 95.0 to 99.0/RON<br/> Judgement: 60.0 to 120.0/RON
Measuring Range For Automobile Diesel Fuels Cetane number: 25 to 75/CN<br/> Cetane index: 20 to 80/CI
Measuring Accuracy Aviation gasoline: ≤ ± 1.5/MON<br/> Gasoline for motor vehicles: ≤ ± 1.5/RON, ≤ ± 1.5/MO<br/> Automobile diesel fuels: ≤ ± 2.6/CN, ≤ ± 2.6/CI<br/> Regression sample retest: ≤ ± 0.5/RON, ≤ ± 0.5/MON<br/> Regression sample measurement: ≤ ± 1.5/RON, ≤ ± 1.5/MON<br/> Calibration accuracy: ≤ ± 0.2/RON, ≤ ± 0.2/MON
Precision (Confidence Level 95%) Reproducibility: ≤ ± 0.5/RON<br/> Repeatability: ≤ ± 0.2/RON
Minimum Scale 0.1/RON,    0.1/MON,   0.1/CI
Response Time 1 min
Ambient Temperature 10°C to 35°C
Humidity < 85% RH
Test Result LCD display, it can store and print
Power Supply AC (220 ± 10%) V, (50 ± 1) Hz
  • Octane number test results meets the standards of ASTM D2699-86
  • Diesel fuel test results meets the standards of ASTM D613 - 18a
  • Highly precise sensors
  • Displays RON, MON and AK (antiknock) index simultaneously
  • Calculates Cetane number automatically
  • Digital transmission technology to transfer data
  • Least variation in values
  • Requires only 150 ml of test sample
  • Results displayed within 1 min
  • LCD display
  • Can store data
It is used in petroleum and oil industry to determine MON, RON, AK index values for gasoline and Cetane number for diesel.

Octane Number & Cetane Number Tester

Portable Octane Number and Cetane Meter LOCT-A20

Portable Octane Number and Cetane Meter LOCT-A20

  • Measurement item
  • motor gasoline and diesel
  • measurement unit of octane is ON
  • 40 to 120
  • Permissible error of octane
  • ± 0.5 max

Automatic Bomb Calorimeter

Automatic Bomb Calorimeter LABC-B11

Automatic Bomb Calorimeter LABC-B11

  • Calorimeter type
  • Isoperibol
  • Oxygen filling
  • Semi-automatic
  • Bomb volume
  • 282 ml
Automatic Bomb Calorimeter LABC-A10

Automatic Bomb Calorimeter LABC-A10

  • Calorimeter type
  • Isoperibol
  • Temperature range
  • 5 to 40°C
  • Measurement range
  • 5 to 40 MJ/ kg
Automatic Bomb Calorimeter LABC-B10

Automatic Bomb Calorimeter LABC-B10

  • Calorimeter type
  • Isoperibol
  • Oxygen filling
  • Fully automatic oxygen filling & releasing, fully automatic bomb raising & lowering
  • Bomb volume
  • 250 ml
Automatic Bomb Calorimeter LABC-A11

Automatic Bomb Calorimeter LABC-A11

  • Calorimeter type
  • Isoperibol
  • Temperature range
  • 5 to 40°C
  • Measurement range
  • 5 to 40 MJ/ kg

Acid and Alkali Tester

Acid Number and Acidity Tester LAAT-A11

Acid Number and Acidity Tester LAAT-A11

  • Ambient temperature
  • ≤ 35 °C
  • Relative humidity
  • ≤ 85 %
  • Precision of titration tube
  • Scale division is 0.02 ml
Base Number Tester LAAT-A13

Base Number Tester LAAT-A13

  • Volumetric analysis
  • Titration condensation: 0.1 N; Controlling accuracy: ≤ ± 0.02 ml
  • Automatic acid titration
  • Titration condensation: 0.1 N; Controlling accuracy: ≤ ± 0.1 pH
  • Automatic potential control
  • Titration condensation: 0.1 N; Controlling accuracy: ≤ 10 mV
Water Soluble Acid and Alkali Tester LAAT-A10

Water Soluble Acid and Alkali Tester LAAT-A10

  • Graduated flask
  • 100 ml,50 ml
  • Conical flask
  • 100ml
  • Separatory funnel
  • 250ml
Acid Number Tester LAAT-A12

Acid Number Tester LAAT-A12

  • Measurement range
  • ≥0.05 mg KOH/g
  • Potential measurement range
  • 0 to 1800.0 mV
  • Burette volume
  • 10 mL

Aniline Test Equipment

Aniline Point Tester LAPT-A11

Aniline Point Tester LAPT-A11

  • Temperature controlling accuracy
  • ≤ 0.5 ℃
  • Temperature controlling range
  • Room temperature ~ 200 ℃
  • Power supply for illumination
  • 5 V
Aniline Point Tester LAPT-A10

Aniline Point Tester LAPT-A10

  • Measurement range
  • Room temperature ~ 150°C
  • Stirring speed
  • 0 ~ 1200 r / min
  • Heating power
  • 25 W

Closed Cup Flash Point Tester

Automatic PMCC Flash Point Tester LCFP-A13

Automatic PMCC Flash Point Tester LCFP-A13

  • Ambient temperature
  • 10 °C ~ 40 ℃
  • Relative humidity
  • ≤ 80 %
  • Ignition Mode
  • electron igniter / gas flame
Automatic PMCC Flash Point Tester LCFP-A11

Automatic PMCC Flash Point Tester LCFP-A11

  • Ambient temperature
  • 10 °C ~ 40 °C
  • Relative humidity
  • ≤ 80 %
  • Measurement Range
  • Ambient Temperature ~ 250 °C
PMCC Flash Point Tester LCFP-A10

PMCC Flash Point Tester LCFP-A10

  • Ambient temperature
  • ≤ 35 °C
  • Relative humidity
  • ≤ 85 %
  • Temperature range
  • 5 °C ~ 110 °C, Each scale division is 0.5 °C; 20 °C ~ 150 °C, Each scale division is 1.0 °C; 90 °C ~ 370 °C, Each scale division is 2 °C