Atomic Absorption spectrophotometer comes with flame, graphite furnace and hydride generation system to meet different customer demand. It is provided with deuterium hollow cathode lamp to eliminate the interference of molecular absorption and Titanium Burner to improve the analysis efficiency and accuracy of the flame. The autosampler has integrated graphite furnace design with high-precision syringes to enter volume as minimum as 0.5μl with intelligent online dilution and concentration function. It has great applications research and medicine, environmental science and other industries.

Wavelength range 180 – 900 nm
Spectral Bandwidth 0.1 nm,0.2 nm,0.4 nm, 1.0 nm, 2.0 nm automatic setting
Wavelength accuracy ≤ 0.15 nm
Wavelength repeatability ± 0.1 nm
Baseline drift ≤ ± 0.002 Abs/30 min (Static) ≤ ± 0.005 Abs/30 min (Dynamic)
Sample Volume 1 - 100 μl
The volume of sample better than 1 %(at the time of 10 mL - 100 mL)
Repeated Sampling Frequency up to 99 Times
Cleaning and waste container volume Each 500 mL
Absorbance Range 0 - 4 A
The Program Automatic temperature control up to 20 order
Temperature Range room temperature to 3000 ℃
Detector imported photomultiplier tube
Heating Mode vertical heating
Temperature Control Method Vertical optical temperature monitoring graphite tube wall temperature
Temperature Control The furnace enriched up to 20 times
Lamp holder ≤ 6 lamps automatic turret, automatic alignment
Lamp power supply mode pulsed power supply
Optical System Large 1800 /mm grating ruling, full closed optical system
Atomization Chamber Polymer explosion-proof spray chamber
Characteristics Volume 0.5 × 10<sup>-12</sup>g (Cd)
Characteristic concentration (Cu) 0.015 μg / mL / 1 %
Detection Limit 0.4 × 10<sup>-12</sup>g (Cd)
Detection Limit (Cu) 0.002 μg/mL
Burner Full titanium combustion head, 50 mm or 100 mm general combustion head
Nebulizer Atomizer efficient glass atomizer,can also be customized
Precision RSD ≤ 0.5
Ignition Type Microcomputer control, automatic ignition
Sample Tray 70 sample cups, 6 reagent cup
The Smallest Lincrement 0.1 μl
Safety measures The graphite tube damage, water flow Air pressure and other alarm temperature overheating protection
Gas Control Automatic gas control system
Measurement Flame method, Hydride generation-Atomic absorption method
Concentration calculation Standard curve method(1 - 3 times curve), automatic fitting
The Cooling Water Can choose cooling water circulation system
The number of repeated measurements 1 to 99, automatic calculation of average concentration, standard deviation, relative standard deviation.
Print results Print the final stages of test data or analysis. The results can be exported into Excel worksheet.
Power supply 110 / 220 V (+5 % ~ (-10) %), 60 / 50 Hz; 5000 VA
  • High precision automatic optical system
  • Graphite furnace temperature control
  • High technical indicators
  • Deuterium lamp for background correction system
  • Polymer automization chamber
  • Powerful, intelligent user-friendly design
  • Automatic analysis & Sampler
Atomic Absorption spectrophotometer is used in scientific research, quality control, disease control, environmental protection, metallurgy, agriculture, chemical industry, and analysis of samples, equipment maintenance, simple and convenient.

Atomic Absorption Spectrophotometer

Labtron Atomic Absorption Spectrophotometer makes use of the modern in technology. It is acquired after thorough research into the desires of the diagnostic community. It has all the power, performance and speed necessitated in today’s modern laboratory.

Atomic Absorption Spectrophotometer LAAS-A10

Atomic Absorption Spectrophotometer LAAS-A10

  • Monochromator
  • Czerny-Turner
  • Wavelength range
  • 190 – 900 nm
  • Spectral Bandwidth
  • 0.2,0.4,1.0,2.0 nm, multi-speed automatic switching
Flame Atomic Absorption Spectrophotometer LAAS-A12

Flame Atomic Absorption Spectrophotometer LAAS-A12

  • Wavelength range
  • 190 nm ~ 900 nm
  • Spectral bandwidth
  • 0.1 nm, 0.2 nm, 1.0 nm, 2.0 nm
  • Wavelength accuracy
  • ± 0.25 nm
Atomic Absorption Spectrophotometer LAAS-A21

Atomic Absorption Spectrophotometer LAAS-A21

  • Wavelength range
  • 180 – 900 nm
  • Spectral Bandwidth
  • 0 nm, 0.2 nm, 0.4 nm, 1.0 nm, 2.0 nm (5 steps with automatic changeover)
  • Wavelength accuracy
  • ≤ 0.15 nm
Atomic Absorption Spectrophotometer LAAS-A20

Atomic Absorption Spectrophotometer LAAS-A20

  • Wavelength range
  • 180 - 900 nm
  • Spectral Bandwidth
  • 0, 0.2, 0.4, 1.0, 2.0nm (Automatic setting)
  • Wavelength accuracy
  • ≤ 0.15 nm

Double Beam UV/Vis Spectrophotometer

Our range of Double Beam UV/VIS spectrophotometers offer long optical path which ensure high accuracy and stability. Its design measures the transmittance of the sample and solvent simultaneously. It is highly precise and performs powerful analysis.

Double beam UV-Visible Spectrophotometer LUS-B15

Double beam UV-Visible Spectrophotometer LUS-B15

  • Wavelength range
  • 190 ~ 1100 nm
  • Spectral bandwidth
  • 2 nm
  • Wavelength accuracy
  • 0.5 nm
Double Beam UV-Vis Spectrophotometer LUS-B11

Double Beam UV-Vis Spectrophotometer LUS-B11

  • Wavelength range
  • 190 to 1100 nm
  • Spectral bandwidth
  • 1.8 nm
  • Optical system
  • Double beam; 1200 lines/mm grating
Double Beam UV/Vis Spectrophotometer LUS-B31

Double Beam UV/Vis Spectrophotometer LUS-B31

  • Wavelength range
  • 190 to 1100 nm
  • Spectral bandwidth
  • 1 nm
  • Wavelength Accuracy
  • ± 0.1nm @ 656.1 nm, ± 0.3 nm @ all
Double Beam UV-Vis Spectrophotometer LUS-B13

Double Beam UV-Vis Spectrophotometer LUS-B13

  • Wavelength Range
  • 190 to 1100 nm
  • Spectral Bandwidth
  • 1.0 nm
  • Optical System
  • Double beam

Nano Spectrophotometer

We produce a wide range of Nano spectrophotometer for qualitative and quantitative analysis of DNA/RNA in the sample. Our product is highly sensitive and requires only 0.5-2µl of sample for analysis.

Nano Spectrophotometer LNS-B20

Nano Spectrophotometer LNS-B20

  • Wavelength Range
  • 200 to 800 nm
  • Sample Size
  • 0.5 to 2.0 µl
  • Path length
  • 0.05 mm 0.2 mm 1.0 mm
Nano Spectrophotometer LNS-A20

Nano Spectrophotometer LNS-A20

  • Wavelength range
  • 190 to 850 nm
  • Wavelength accuracy
  • ± 1 nm
  • Wavelength Resolution
  • 2 nm (FWHM at Hg 546 nm)
Nano Spectrophotometer LNS-C13

Nano Spectrophotometer LNS-C13

  • Cuvette
  • Yes
  • Temperature
  • 4 ºC - 42 ºC (Heating & Cooling)
  • PC
  • Inbuilt
Nano Spectrophotometer LNS-A21

Nano Spectrophotometer LNS-A21

  • Wavelength range
  • 200 - 850 nm
  • Path length
  • 1 mm, 2 mm, 5 mm, 10 mm
  • Wavelength accuracy
  • ± 1 nm

Single Beam UV/Visible Spectrophotometer

We manufacture highly precise UV/Vis automatic scanning spectrophotometer with wavelength ranging from 190-1100nm. It can perform quantitative measurement, photometric measurement, spectrum scanning, DNA/Protein analysis. It is in demand for its user-friendly operations

Single Beam UV/Vis Spectrophotometer LUS-A51

Single Beam UV/Vis Spectrophotometer LUS-A51

  • Wavelength range
  • 190 to 1100 nm
  • Spectral bandwidth
  • 1 nm
  • Wavelength Accuracy
  • ± 0.1nm @ 656.1 nm, ± 0.3 nm @ all
Single Beam UV/Visible Spectrophotometer LUS-A30

Single Beam UV/Visible Spectrophotometer LUS-A30

  • Wavelength Range
  • 190 ~ 1100 nm
  • Setting Wavelength
  • Automatic
  • Spectral Bandwidth
  • 4 nm
Single Beam UV/Visible Spectrophotometer LUS-A11

Single Beam UV/Visible Spectrophotometer LUS-A11

  • Wavelength Range
  • 190 ~ 1100 nm
  • Spectral Bandwidth
  • 1.8 nm
  • Wavelength Accuracy
  • ± 0.3 nm
Single Beam UV/Vis Spectrophotometer LUS-A50

Single Beam UV/Vis Spectrophotometer LUS-A50

  • Wavelength range
  • 190 to 1100 nm
  • Spectral bandwidth
  • 2 nm
  • Wavelength Accuracy
  • ± 0.1nm @ 656.1 nm, ± 0.3 nm @ all

Visible Spectrophotometer

Labtron provides extensive range of visible spectrophotometer LVS series which can operate over a wavelength range of 320-1100nm. It brings unmatched performance with outstanding accuracy and precision.

Vis Spectrophotometer LVS-B10

Vis Spectrophotometer LVS-B10

  • Wavelength Range
  • 325 ~ 1000 nm
  • Setting Wavelength
  • Automatic
  • Spectral Bandwidth
  • 2 nm
Visible Spectrophotometer LVS-A21

Visible Spectrophotometer LVS-A21

  • Photometry
  • Single Beam
  • Monochromatic Type
  • Czerny-Turner
  • Wavelength range
  • 325 to 1000nm
Vis Spectrophotometer LVS-C10

Vis Spectrophotometer LVS-C10

  • Wavelength Range
  • 320 ~ 1100 nm
  • Spectral Bandwidth
  • 4 nm
  • Wavelength Accuracy
  • ± 0.5 nm
Visible Spectrophotometer LVS-A30

Visible Spectrophotometer LVS-A30

  • Wavelength range
  • 320 to 1100 nm
  • Spectral bandwidth
  • 2.0 nm
  • Wavelength Accuracy
  • ± 0.8 nm