This device is specifically designed to detect the concentration of ozone with the help of ozone detector. Along with low maintenance and noiseless generator this machine has a well-built corrosion resistant body.

Diameter of holder (mm) 700
Length of each side (mm) 350
Temperature range 0℃ ~ 100℃
Humidity range 30 % - 98 % R.H
Temperature fluctuation ± 0.5 ℃
Speed rate for cooling Ambient ~ 0 ℃ within 20 min
Timing range 0 ~ 999 hours
Ozone concentration 1 ~ 1000PPHM
Sample holder rotate speed 0 ~ 10 r/min (adjustable)
Clamps tensile stretch 5 % ~ 35 %
Max. ozone concentration 120 g O<sub>3</sub>/m³
Ozone output 3.5 g O<sub>3</sub>/h (oxygen input, flow rate 100L/h)
Nominal power 9000 W
Internal dimensions 800 × 1000 × 1000 mm
Overall dimensions (mm) 1280 × 1550 × 2110 mm
Power & voltage AC 380 V 50Hz
  • Use this static and dynamic combined sample holders
  • PID programmable controller with LED touch screen display
  • Equipped with UV detector to detect the concentration of ozone
  • Designed with combination of three control systems- PLC, HMI and SOC
  • Incorporated with protection module for safety voltage
  • Solid and durable structured closed-type compressor unit
  • User-friendly and reliable
  • Stable and require low maintenance
  • Consists of highly efficient low noise ozone generator
  • Made up of corrosion resistant stainless steel body
Applied to various industries such as automobile, rubber & plastics, packaging, medical equipment, colleges and universities, research laboratories etc.

Ozone Test Chamber

Labtron offers ozone test chambers which can simulate ozone atmospheric conditions to be used for aging cracking test of non-metal materials and rubber products, to determine the anti-ozone properties of the products.

Ozone Test Chamber LOC-A14

Ozone Test Chamber LOC-A14

  • Diameter of holder (mm)
  • 900
  • Length of each side (mm)
  • 460
  • Temperature range
  • 0℃ ~ 100℃
Ozone Test Chamber LOC-A12

Ozone Test Chamber LOC-A12

  • Diameter of holder (mm)
  • 600
  • Length of each side (mm)
  • 220
  • Temperature range
  • 0℃ ~ 100℃
Ozone Test Chamber LOC-A11

Ozone Test Chamber LOC-A11

  • Diameter of holder (mm)
  • 400
  • Length of each side (mm)
  • 180
  • Temperature range
  • 0℃ ~ 100℃
Ozone Test Chamber LOC-A10

Ozone Test Chamber LOC-A10

  • Temperature range
  • 0℃ ~ 100℃
  • Humidity range
  • 30 % - 98 % R.H
  • Temperature fluctuation
  • ± 0.5 ℃

Drug Test Chamber

Drug test chambers are designed to conduct stability and shelf life studies on drug and drugs components.

Drug Stability Chamber with Illumination LDST-B12

Drug Stability Chamber with Illumination LDST-B12

  • Volume
  • 500 L
  • Temperature Range(without illumination)
  • 0 - 65 °C
  • Temperature Range(with illumination)
  • 10 °C - 65°C
Drug Stability Test Chamber LDST-A10

Drug Stability Test Chamber LDST-A10

  • Volume
  • 150 L
  • Temperature Range
  • 0 - 65 °C
  • Temperature Fluctuation
  • ± 0.5 °C
Drug Stability Test Chamber LDST-A11

Drug Stability Test Chamber LDST-A11

  • Volume
  • 250 L
  • Temperature Range
  • 0 - 65 °C
  • Temperature Fluctuation
  • ± 0.5 °C
Drug Stability Test Chamber LDST-A21

Drug Stability Test Chamber LDST-A21

  • Interior Volume
  • 225 L
  • Heat load
  • 1000 W
  • Temperature Range
  • 0℃ to 100 ℃

Plant Growth Chamber

Labtron’s plant growth chamber is designed with accurate control of temperature, light, humidity, CO2 and other environmental factors which are necessary for plant growth. These chambers are helpful for researchers to carryout different experiments on plants without any dependency on climatic factors.

Plant Growth Chamber LPGC-B13

Plant Growth Chamber LPGC-B13

  • Chamber Volume
  • 800 L
  • Shelves
  • 3(PCS)
  • Display Resolution
  • 0.1 ℃
Plant Growth Chamber LPGC-A10

Plant Growth Chamber LPGC-A10

  • Chamber Volume
  • 300 L
  • Shelves
  • 3(PCS)
  • Display Resolution
  • 0.1 ℃
Plant Growth Chamber LPGC-A11

Plant Growth Chamber LPGC-A11

  • Chamber Volume
  • 450 L
  • Shelves
  • 3(PCS)
  • Display Resolution
  • 0.1 ℃
Plant Growth Chamber LPGC-A13

Plant Growth Chamber LPGC-A13

  • Chamber Volume
  • 1000 L
  • Shelves
  • 3(PCS)
  • Display Resolution
  • 0.1 ℃

Salt Spray Test Chamber

Labtron offers wide range of salt spray corrosion test systems with ability to test the corrosive resistant of products. Our user friendly products suit our clients' requirement and hence, continue to be in demand.

Salt Spray Test Chamber LSSC-A13

Salt Spray Test Chamber LSSC-A13

  • Testing room capacity
  • 780 L
  • Temperature range
  • Ambient to +60°C
  • Humidity range
  • 95% to 98% RH
Salt Spray Test Chamber LSSC-A15

Salt Spray Test Chamber LSSC-A15

  • Testing room capacity
  • 1600 L
  • Temperature range
  • Ambient to +60°C
  • Humidity range
  • 95% to 98% RH
Salt Spray Test Chamber LSSC-A11

Salt Spray Test Chamber LSSC-A11

  • Testing room capacity
  • 326 L
  • Temperature range
  • Ambient to +60°C
  • Humidity range
  • 95 to 98% RH
Salt Spray Test Chamber LSSC-A10

Salt Spray Test Chamber LSSC-A10

  • Testing room capacity
  • 110 L
  • Temperature range
  • Ambient to +60°C
  • Humidity range
  • 95 to 98% RH

Sand Test Chamber

In order to increase the durability of product, we need to test its performance under various conditions. Keeping this in mind, Labtron presents sand test chambers which simulate dust and sand conditions in a controlled atmosphere.

Sand and Dust Test Chamber LSC-A13

Sand and Dust Test Chamber LSC-A13

  • Temperature range
  • Ambient to + 50 ℃
  • Relative Humidity
  • < 30 % RH
  • Normal wire diameter
  • 50 um
Sand and Dust Test Chamber LSC-A10

Sand and Dust Test Chamber LSC-A10

  • Temperature range
  • Ambient to + 50 ℃
  • Relative Humidity
  • < 30 % RH
  • Normal wire diameter
  • 50 um
Sand and Dust Test Chamber LSC-A12

Sand and Dust Test Chamber LSC-A12

  • Temperature range
  • Ambient to + 50 ℃
  • Relative Humidity
  • < 30 % RH
  • Normal wire diameter
  • 50 um
Sand and Dust Test Chamber LSC-A11

Sand and Dust Test Chamber LSC-A11

  • Temperature range
  • Ambient to + 50 ℃
  • Relative Humidity
  • < 30 % RH
  • Normal wire diameter
  • 50 um