Gas Chromatography LGC-B11 is a benchtop unit with advanced flow controller (AFC) technology. System has digital control mode and polar capillary columns to separate polar analytes. GC oven is capable of 9 temperature program ramps and hold steps, and features rapid cooling: 250 °C to 50 °C < 10 minutes. Accurate flow rate control via AFC has higher level repeatability of retention time and peak area, enabling specific level of analysis by means of dual FID detectors.

Oven <table class='table table-striped table-bordered table-responsive'><tr><td><strong>Maximum capacity</strong></td><td>22 L</td></tr><tr><td><strong>Temperature range</strong></td><td>RT + 5 ℃ to 400 ℃</td></tr><tr><td><strong>Temperature accuracy</strong></td><td>± 0.1 ℃</td></tr><tr><td><strong>Temperature program</strong></td><td>9-phase/ 10 platform</td></tr><tr><td><strong>Program total time</strong></td><td>9999.9 min</td></tr><tr><td><strong>Maximum temperature heating rate</strong></td><td>0.1 to 60 ℃/ min</td></tr><tr><td><strong>Maximum cooling rate</strong></td><td>˂ 10 mins (250 to 50 ℃)</td></tr></table>
Sample injector <table class='table table-striped table-bordered table-responsive'><tr><td><strong>Temperature range</strong></td><td>RT+ 7 ℃ to 420 ℃</td></tr><tr><td><strong>Temperature control</strong></td><td>Automatic</td></tr><tr><td><strong>Injector type</strong></td><td>Column or split</td></tr><tr><td><strong>Maximum sample inlet</strong></td><td>3 pcs</td></tr><tr><td><strong>Carrier gas flow type</strong></td><td>Constant pressure</td></tr><tr><td><strong>Pre column pressure range</strong></td><td>0 to 400 kPa</td></tr><tr><td><strong>Pre column pressure accuracy</strong></td><td>0.1 kPa</td></tr><tr><td><strong>Mobile phase flow range</strong></td><td>H2: 0 to 200 ml/min, N2: 0 to 150 ml/min</td></tr></table>
Detector <table class='table table-striped table-bordered table-responsive'><tr><td><strong>Temperature range</strong></td><td>RT + 7 ℃ to 420 ℃</td></tr><tr><td><strong>Maximum installation</strong></td><td>Dual detector</td></tr><tr><td><strong>Flame ignition mode</strong></td><td>Automatic</td></tr><tr><td><strong>Flame Ionization Detector (FID)</strong></td><td>Logarithmic amplifier <br/> High voltage switch control <br/> Baseline signal display <br/> Ignition coil control <br/> Detection limit: ≤3 ×10 to 12 g/s (Sample: n-hexadecane) <br/> Baseline noise: ≤ 5 × 10 <sup> - 14 </sup> A <br/> Baseline draft: ≤ 6 × 10 <sup> -13 </sup> A <br/> Dynamic range: 10 <sup> 7 </sup> <br/> RSD: ≤ 3 %</td></tr></table>
Power supply AC 220 V ± 22 V, 50 Hz ± 0.5 Hz, 3000 W
Packing dimension 1020 × 660 × 740 mm
Gross Weight 82 kg
Net weight 70 kg
  • 7-inch LCD display specifies temperature, gas flow and heating curve
  • H2 and N2 mobile gas phase with AFC and constant pressure gas flow type
  • Equipped with capillary analysis system and capillary split sampler
  • Injection system incorporates diaphragm cleaning, split flow and auxiliary gas adjustment
  • Standard unit for high-speed analysis with polar capillary column
  • PEG-20M and FFAP stationary phase polar capillary columns can be coupled
  • Dual FID detector with automatic flame ignition and baseline signal display
  • Self-diagnostic and automatic fault recognition function
  • Multi-core and 32-bit embedded hardware system ensures the reliable operation
  • Equipped with chromatography workstation software to process data
  • Memory function can store 20 sample test data
  • RS232 interface and LAN port
Suitable for analysis of trace toxic compounds, monitoring and research in environmental protection, atmosphere and water source pollution. It is widely used for petrol-chemistry, environmental protection, epidemic prevention, pharmacology and scientific research.

Gas Chromatography

Ion Chromatography

Ion chromatograph system LICS-A22

Ion chromatograph system LICS-A22

  • Ion Chromatographic pump
  • TypeHigh pressure and low pulse double plunger tandem advection pumpMaximum pressure35 MPa (PEEK)Display pressure accuracy≤ 0.1 MPaFlow stability(0.2 to 0.5) ml/ min ≤ 3 % , (0.5 to 1.0) ml/ min ≤ 2 %, > 1.0 ml/ min ≤ 2 %Flow range0.001 to 9.999 ml/ minPressure pulse≤ 0.5 %
  • Numerical control and electromagnetic injection
  • Maximum pressure35 MPaContact material of the rotorPEEKControl modeBy Stepper motorPower supplyDC 24 V
  • Column heater
  • Operating temperature rangeRoom temperature 20 to 60°C ( 68 to 140°F)Controlling temperature accuracy± 0.01°CAllowable deviation of column heater temperature± 2°CTemperature stability≤ 1°C/ h
Ion chromatograph system LICS-A21

Ion chromatograph system LICS-A21

  • Ion Chromatographic Pump
  • TypeHigh pressure and low pulse double plunger tandem advection pumpMaximum pressure35 MPa (PEEK)Pressure display accuracy≤ 0.1 MPaFlow stability(0.2 to 0.5) ml/ min ≤ 3 % (0.5 to 1.0) ml/ min ≤ 2 % > 1.0 ml/ min 2 %Flow range0.001 to 9.999 ml/ minPressure pulse≤ 0.5%
  • Conductivity detector
  • TypeTemperature Control and Bipolar Conductivity DetectorDetection modeBipolar conductivity detectionCell volume≤ 0.8 µLDetection range0 to 45000 µS/ cmDetection resolution≤ 0.0020 nS/ cmOutput voltage- 6000 to +6000 mV (adjustable)Baseline noise≤ 0.05 % F.S.Baseline drift≤ 3 % FS/ 30 minOperating temperature rangeRoom temperature +5 to 60°C (41 to 140°F)Controlling temperature accuracy± 0.01°CMaximum pressure10 MPaLinear range≥ 103Instruments linearity≥ 0.999Quantitative repeatability≤ 1.0 %Qualitative repeatability≤ 1.0 %Minimum detectable concentrationCl ≤ 0.0005 ug/ ml BrO3 ≤ 0.001 ug/ ml Li+ ≤ 0.001 ug/ ml
  • Flow system
  • Plastic flow pathMade of PEEK materialsSix way ValvePEEK material, 5000 psi pressure, independent automatic collection and flow function
Ion chromatograph system LICS-A20

Ion chromatograph system LICS-A20

  • Ion Chromatographic Pump
  • TypeHigh pressure and low pulse double plunger tandem advection pumpMaximum pressure35 MPa (PEEK)Pressure display accuracy≤ 0.1 MPaFlow stability(0.2 to 0.5) ml/ min ≤ 3 % (0.5 to 1.0) ml/ min ≤ 2 % > 1.0 ml/ min 2 %Flow range0.001 to 9.999 ml/ minPressure pulse≤ 0.5%
  • Conductivity detector
  • TypeTemperature Control and Bipolar Conductivity DetectorDetection modeBipolar conductivity detectionCell volume≤ 0.8 µLDetection range0 to 35000 µS/ cmDetection resolution≤ 0.0020 nS/ cmOutput voltage- 6000 to +6000 mV (adjustable)Baseline noise≤ 0.05 % F.S.Baseline drift≤ 3 % FS/ 30 minOperating temperature rangeRoom temperature +5 to 60°C (41 to 140°F)Controlling temperature accuracy± 0.01°CMaximum pressure10 MPaLinear range≥ 103Instruments linearity≥ 0.999Quantitative repeatability≤ 1.0 %Qualitative repeatability≤ 1.0 %Minimum detectable concentrationCl ≤ 0.0005 ug/ ml BrO3 ≤ 0.001 ug/ ml Li+ ≤ 0.001 ug/ ml
  • Flow system
  • Plastic flow pathMade of PEEK materialsSix way ValvePEEK material, 5000 psi pressure, independent automatic collection and flow function

GC-MS

Gas chromatography mass spectrometry GC-MS-879

Gas chromatography mass spectrometry GC-MS-879

  • Gas Chromatography Specifications
  • Model NoGC-87Flow rate1 ~ 1.5 ml / minMaximum flow rate10 ml / minInlet temperature450 °CPressure range0 ~ 100 psiHeating rateUpto 120 °C / minRoom temperature4 °C ~ 450 °CPressure control modeElectronic pressure control ( Supports CV and CC )Split modeSplit / split lessSplit ratio1000 : 1Temperature programming7 stages / 8 platformsAuto samplerOptional
  • Mass Spectrometry Specifications
  • Model NoMS-89Mass range1.5 ~ 1000 amuIon – source temperature100 °C ~ 350 °CGC-MS interface temperature450 °CScan rateUpto 10000 amu/sStability± 0.10 amu / 48 hrs.Filament emission current0 ~ 350 µAEI source ionization energy5 eV ~ 250 eVResolutionUnit resolutionDetectorHigh energy dynode electron multiplierSensitivityFull scan ( S / N is ≥ 30 : 1 )VacuumTurbo molecular pump ( 67 L/s )

Portable Ion Chromatograph

Ion Chromatograph LPIC-A10

Ion Chromatograph LPIC-A10

  • Chromatographic Pump
  • TypeHigh-pressure and low –pulse double plunger tandem advection pumpMaximum Pressure35 MPa (PEEK)Flow Range0.001 to 9.999 mL/minFlow accuracy± 0.5 %Flow RepeatabilityRSD ≤ 0.1%Flow stability(0.2 to 0.5) mL/min, ≤ 3 % (0.5 to 1.0) mL/min, ≤ 2 % >1.0 mL/min, ≤ 2 %
  • Built-in Heat conduction type column heater
  • Temperature rangeRoom temperature +5°C to 60°C (41 to 140°F)Allowable deviation± 1°CTemperature stability≤ 0.5°C/h
  • Electromagnetic injection valve
  • Maximum pressure35 MPaControl modeBy stepper motorPower supply24 V (DC)