| Chromatographic Pump | <table class='table table-striped table-bordered table-responsive'><tr><td><strong>Type</strong></td><td>High-pressure and low –pulse double plunger tandem advection pump</td></tr><tr><td><strong>Maximum Pressure</strong></td><td>35 MPa (PEEK)</td></tr><tr><td><strong>Flow Range</strong></td><td>0.001 to 9.999 mL/min</td></tr><tr><td><strong>Flow accuracy</strong></td><td>± 0.5 %</td></tr><tr><td><strong>Flow Repeatability</strong></td><td>RSD ≤ 0.1%</td></tr><tr><td><strong>Flow stability</strong></td><td>(0.2 to 0.5) mL/min, ≤ 3 %<br/> (0.5 to 1.0) mL/min, ≤ 2 %<br/> >1.0 mL/min, ≤ 2 %</td></tr></table> |
| Built-in Heat conduction type column heater | <table class='table table-striped table-bordered table-responsive'><tr><td><strong>Temperature range</strong></td><td>Room temperature +5°C to 60°C (41 to 140°F)</td></tr><tr><td><strong>Allowable deviation</strong></td><td>± 1°C</td></tr><tr><td><strong>Temperature stability</strong></td><td>≤ 0.5°C/h</td></tr></table> |
| Electromagnetic injection valve | <table class='table table-striped table-bordered table-responsive'><tr><td><strong>Maximum pressure</strong></td><td>35 MPa</td></tr><tr><td><strong>Control mode</strong></td><td>By stepper motor</td></tr><tr><td><strong>Power supply</strong></td><td>24 V (DC)</td></tr></table> |
| Digital and temperature control detection system | <table class='table table-striped table-bordered table-responsive'><tr><td><strong>Type</strong></td><td>Temperature control and bipolar conductivity detector</td></tr><tr><td><strong>Detection type</strong></td><td>Bipolar conductivity detection</td></tr><tr><td><strong>Cell volume</strong></td><td>≤ 0.8 µL</td></tr><tr><td><strong>Measurement range</strong></td><td>0 to 45000 µ S/cm (adjustable)</td></tr><tr><td><strong>Detection resolution</strong></td><td>≤ 0.0020 nS/cm</td></tr><tr><td><strong>Output voltage</strong></td><td>-6000 to 6000 mV (adjustable)</td></tr><tr><td><strong>Temperature range</strong></td><td>Room temperature +5°C to 60°C (41 to 140°F)</td></tr><tr><td><strong>Temperature accuracy</strong></td><td>± 0.01°C</td></tr><tr><td><strong>Maximum pressure</strong></td><td>10 MPa</td></tr><tr><td><strong>Baseline drift</strong></td><td>≤ 20 % FS/30 min</td></tr><tr><td><strong>Baseline noise</strong></td><td>≤0.5 % FS</td></tr><tr><td><strong>Instrument linearity</strong></td><td>≥ 0.999</td></tr><tr><td><strong>Quantitative Repeatability</strong></td><td>≤0.5 %</td></tr><tr><td><strong>Qualitative Repeatability</strong></td><td>≤2 %</td></tr><tr><td><strong>Minimum detectable concentration</strong></td><td>Cl-≤0.005 µg/mL<br/> Li+ ≤0.005 µg/mL</td></tr></table> |
| Flow system | <table class='table table-striped table-bordered table-responsive'><tr><td><strong>Plastic path flow</strong></td><td>Made of PEEK material</td></tr><tr><td><strong>Six way valve</strong></td><td>PEEK material pressure 5000 psi, independent automatic collecting and flow function</td></tr></table> |
| Panel computer | <table class='table table-striped table-bordered table-responsive'><tr><td><strong>Display screen</strong></td><td>12.3 inch</td></tr><tr><td><strong>Internal memory</strong></td><td>2G</td></tr><tr><td><strong>Weight</strong></td><td>786 g</td></tr></table> |
| External size (L × W × H) | 440 × 226 × 420 mm |
| Net weight | 8 kg |
| Gross weight | 11 kg |