Handheld C2H4 Ethylene Gas Detector LEGD-A10 is a portable device with built-in sampling pump having a flow rate of 1 L/min. It meets IP-66 standards which makes it suitable for use in harsh environmental conditions. Rapid speed of sampling, high flow rate, least detection time, compact design, plastic housing, storage space, etc. are some of the features which ensures accurate results in few minutes. It is used in chemical industry, food industry, etc.

Sampling With internal sampling pump, flow rate is up to 1 L/min, ten grades of pumping suction for selection
Gas Ethylene C2H4
Measure Range 0 to 1000 ppm
Resolution 1ppm
Precision 3 to 10% F.S.
Response Time ≤ 10 s
Repeatability ≤ ± 1%
Zero Shift ≤ ± 1%(F.S./year)
Display LCD dot matrix display
Temperature -20°C to 50°C
Humidity 0 to 95 % RH
Degree of Protection IP-66
Alarm Sound, light, vibration
Recovery Time ≤ 10 s
Linearity Error ≤ ± 1%
Gas Unit Units are switchable
Battery 3.6 V 2300 mAh lithium polymer rechargeable battery<br/> operate time is about 12 h continuously<br/> charging time: 4 to 6 h
Operating Time 100 h (pump off)
Dimensions 205×75×32 mm
Weight 300 g
  • Highly precise sensors for accurate detection
  • Water-proof, dust-proof, explosion-proof
  • Response in less than 30s
  • Options for units between ppm and mg/m3
  • Automatic calibration mode
  • Restore factory setting option
  • Audio, visual alarm system
  • Threshold values for alarm can be set
  • 100000 sets can be stored and also re-viewed
  • Data transfer through USB (optional)
  • Long working hours and rechargeable battery
  • Dense plastic housing
  • Compact size and easy to use
  • Aluminium case to carry the device
It is used to detect ethylene gas. Extensively used in brewing and fermentation industry, cold storage places, agricultural research, chemical labs, paper making industry, bio-pharmaceutical plant etc.

Gas Detectors

Portable Single Gas Detector LPSG-A10

Portable Single Gas Detector LPSG-A10

  • Sampling method
  • Diffusion
  • Measurement principle
  • Electrochemical (oxygen, toxic gases), Catalytic combustion (flammable gases), Infrared principle (carbon dioxide gas)
  • Detector gas
  • Flammable gases, oxygen gas, toxic and harmful gases
Portable 2 in 1 gas detector LPTG-A10

Portable 2 in 1 gas detector LPTG-A10

  • Sampling method
  • Diffusion
  • Sensor type
  • CO2: solid electrolyte sensor, O2:electrochemical sensor
  • Detection range
  • CO2:0.04 to 5.00 % and O2:0.0 to 30.0 %
Portable Multiple Gas Detector LPMG-A10

Portable Multiple Gas Detector LPMG-A10

  • Sampling Method
  • Diffusion
  • Working conditions
  • Temperature -20 to 50°C Pressure 0.9 to 1.1 (standard atmospheric pressure) Humidity 10 to 95 % RH (no dew condensation)
  • Explosion proof grade
  • Exia II CT3
Portable SO2Gas Detector LPSG-A20

Portable SO2Gas Detector LPSG-A20

  • Gas detected
  • Sulfur dioxide SO2
  • Detection principle
  • Electrochemistry
  • Sampling method
  • Pumping suction, flow rate can up to 1L/min, ten grades of pumping suction for selection.

Digital Differential Pressure Meter

Digital Differential Pressure Meter LDPM-A20

Digital Differential Pressure Meter LDPM-A20

  • Measuring range
  • ± 500 Pa
  • Repeatability
  • ± 0.2 % FS
  • Resolution
  • 0.1 Pa
Digital Differential Pressure Meter LDPM-A10

Digital Differential Pressure Meter LDPM-A10

  • Measuring range
  • 0 ∼ 125 Pa
  • Accuracy
  • 0 ± 0.2 Pa (liner error) ± 1 %
  • Operating temperature range
  • 0 °C ∼ 50 °C

Handheld Ozone Tester

Handheld Ozone Tester LHOT-A10

Handheld Ozone Tester LHOT-A10

  • Measurement range
  • 0 ppm ∼ 5 ppm
  • Resolution
  • 0.001 ppm ( 0 ppm ∼ 5 ppm )
  • Temperature range
  • ˗ 40 °C ∼ 120 °C

Online Ozone Meter

Online Ozone Meter LOOM-A10

Online Ozone Meter LOOM-A10

  • Ozone measurement range
  • 0 ppm ∼ 5 ppm, 0 ppm ∼ 100 ppm, 0 ppm ∼ 300 ppm, 0 ppm ∼ 600 ppm ( Optional )
  • Flow rate
  • 1.5 L/min
  • Accuracy
  • 0.01 ppm or 3 % of reading

UV-Absorption Ozone Meter

UV Absorption Ozone Meter LUOM-A10

UV Absorption Ozone Meter LUOM-A10

  • Ozone measurement range
  • 0 ppm ∼ 100 ppm/ 0 ppm ∼ 1000 ppm
  • Flow rate
  • 1 L/min
  • Accuracy
  • 0.01 ppm