Portable NO2 Gas Detector LPSG-A21 is a fast response and high accuracy gas measurement device with 0 to 1000 ppm range. Its internal sampling pump with fast sampling speed and high flow rate, ensures the accurate response time of the detector. Portable nature, small size ait offers role in special high intensity engineering plastic housing, suitable for different kinds of situation and environment. The gas concentration unit ppm and mg/m3 can be shifted quickly and also the local time can be shown on the screen.

Gas detected NO<sub>2</sub>
Detection principle Electrochemistry
Sampling method Pumping suction, flow rate can up to 1L/min, ten grades of pumping suction for selection.
Measure range 0 to1000 ppm
Resolution 1 ppm
Precision 2 % fs
Signal output High-speed data transmission by USB, available for data downloading and printing
Response time ≤ 10 s
Repeatability ≤ ± 1 %
Zero shift ≤ ± 1 % (fs/year)
Operating language English
Temperature -20° C to 50 °C
Explosion-proof Exib ll CT4
Alarm mode Sound, light, vibration
Recovery time ≤ 10 s
Linearity error ≤ ± 1 %
Display LCD dot matrix display
Gas unit Units are switchable
Humidity 0 to 95 % RH
Degree of protection IP66
Operating time 100 h (pump off)
Dimension 205 × 75 × 32 mm
Weight 300 g
  • Monitor the NO2 gas concentration in environment
  • Built in micro sampling pump and 10 grades of suction are available
  • High speed data transmission by USB, which can download and print data
  • Equipped by self-calibration and zero calibration function, makes the detection more accurate and reliable
  • Feature by aluminium suitcase and charging adapter
  • Two stages alarm with sound and light, alarm point is settable
  • The gas concentration unit ppm and mg/m3 can be shifted quickly
  • Rechargeable lithium polymer battery of large capacity
  • LCD dot matrix display, the gas type, unit, concentration
  • Employing pumping sampling method and the pumping suction is adjustable
Portable NO<sub>2</sub>Gas Detector is used in petrochemical and chemical industry, agriculture environment protection, electronic, food, pharmaceutical industry, bio-pharmaceutical plant, green household and fermentation process.

Gas Detectors

Handheld C2H4 Ethylene Gas Detector LEGD-A10

Handheld C2H4 Ethylene Gas Detector LEGD-A10

  • Sampling
  • With internal sampling pump, flow rate is up to 1 L/min, ten grades of pumping suction for selection
  • Gas
  • Ethylene C2H4
  • Measure Range
  • 0 to 1000 ppm
Portable 2 in 1 gas detector LPTG-A10

Portable 2 in 1 gas detector LPTG-A10

  • Sampling method
  • Diffusion
  • Sensor type
  • CO2: solid electrolyte sensor, O2:electrochemical sensor
  • Detection range
  • CO2:0.04 to 5.00 % and O2:0.0 to 30.0 %
Portable 10 in 1 Multi Gas Detector LMGD-A10

Portable 10 in 1 Multi Gas Detector LMGD-A10

  • Gas Detected
  • O2 CH4 CO2 VOC CO H2S SO2 CL2 NO2 NH3
  • Detection principle
  • Electrochemical principle (O2 CO H2S SO2 CL2 NO2 NH3) Infrared principle (CH4 CO) Photoionization principles (VOC)
  • Measurement Range
  • O2: 0-30% VOL, CH4: 0-50000 PPM, CO2:0-50000 PPM VOC:0-2000 PPM, CO:0-999 PPM, H2S: 0-200 PPM SO2: 0-25 PPM, CL2: 0-50 PPM, NO2: 0-100 PPM, NH3:0-100 PPM
Portable infrared gas detector LIGD-A10

Portable infrared gas detector LIGD-A10

  • Measurement principle
  • Non-dispersive infrared  (NDIR)
  • Gas Detected
  • SF6: 0 to 50 ppm range/ 0 to 1000 ppm range (as per req.)
  • Detection Uncertainty

Digital Differential Pressure Meter

Digital Differential Pressure Meter LDPM-A10

Digital Differential Pressure Meter LDPM-A10

  • Measuring range
  • 0 ∼ 125 Pa
  • Accuracy
  • 0 ± 0.2 Pa (liner error) ± 1 %
  • Operating temperature range
  • 0 °C ∼ 50 °C
Digital Differential Pressure Meter LDPM-A20

Digital Differential Pressure Meter LDPM-A20

  • Measuring range
  • ± 500 Pa
  • Repeatability
  • ± 0.2 % FS
  • Resolution
  • 0.1 Pa

Handheld Ozone Tester

Handheld Ozone Tester LHOT-A10

Handheld Ozone Tester LHOT-A10

  • Measurement range
  • 0 ppm ∼ 5 ppm
  • Resolution
  • 0.001 ppm ( 0 ppm ∼ 5 ppm )
  • Temperature range
  • ˗ 40 °C ∼ 120 °C

Online Ozone Meter

Online Ozone Meter LOOM-A10

Online Ozone Meter LOOM-A10

  • Ozone measurement range
  • 0 ppm ∼ 5 ppm, 0 ppm ∼ 100 ppm, 0 ppm ∼ 300 ppm, 0 ppm ∼ 600 ppm ( Optional )
  • Flow rate
  • 1.5 L/min
  • Accuracy
  • 0.01 ppm or 3 % of reading

UV-Absorption Ozone Meter

UV Absorption Ozone Meter LUOM-A10

UV Absorption Ozone Meter LUOM-A10

  • Ozone measurement range
  • 0 ppm ∼ 100 ppm/ 0 ppm ∼ 1000 ppm
  • Flow rate
  • 1 L/min
  • Accuracy
  • 0.01 ppm