Labtron LLTT-A12 is designed with cold filter plugging point test along with proper cooling bath. Equipped as per “Test Methods for Cold Filter Plugging Point of Distillate Fuels”.

Ambient temperature (-10)℃ ~ 35 ℃
Relative humidity ≤ 85 %
Sample cup Inner diameter 31.0 ~ 32.0 mm
Sample cup Wall thickness 1.0 ~ 1.5 mm
Sample cup Height 115 ~ 125 mm
Pumping pressure U type differential pressure meter 1961 Pa (200 mm H<sub>2</sub>O)
Total power consumption ≤ 150 W
Power supply AC 220 V ± 10 %, 50 Hz
  • Relative low temperature tester
  • Round glass cup with flat bottom sample cup
  • Equipped with SH/T0248 “Test Methods for Cold Filter Plugging Point of Distillate Fuels
  • Advance Digital display
  • Integrated structure
It can be widely used in petroleum, chemical industries and environmental studies.

Low Temperature Tester

Solidifying Point Tester LLTT-A13

Solidifying Point Tester LLTT-A13

  • Temperature controlling accuracy
  • ± 0.5 ℃
  • Refrigeration system
  • New-type refrigeration compressor
  • Cold trough
  • Two holes in one trough, and same temperature
Freezing Point Tester LLTT-A11

Freezing Point Tester LLTT-A11

  • Freezing point range
  • -54°C to 2°C
  • Cold bath measurement temperature range
  • -70° to 20°C
  • Temperature controlling accuracy
  • ±0.5°C
Solidifying Point and Cold Filter Plugging Point Tester LLTT-A15

Solidifying Point and Cold Filter Plugging Point Tester LLTT-A15

  • Refrigeration system
  • New-type refrigeration compressor
  • Controlling temperature of cold trough
  • Cold trough I: RT ~ (-51) °C, ± 1°; Cold trough II:RT ~ (-80) °C, ± 1 °C
  • Ambient temperature
  • ≤ 30 ℃
Solidifying Point Constant Temperature Water Bath LLTT-A10

Solidifying Point Constant Temperature Water Bath LLTT-A10

  • Capacity
  • 20 L
  • Temperature range
  • Ambient +5°C to 100°C
  • Precision
  • ± 0.1℃

Automatic Bomb Calorimeter

Automatic Bomb Calorimeter LABC-A11

Automatic Bomb Calorimeter LABC-A11

  • Calorimeter type
  • Isoperibol
  • Temperature range
  • 5 to 40°C
  • Measurement range
  • 5 to 40 MJ/ kg
Automatic Bomb Calorimeter LABC-B11

Automatic Bomb Calorimeter LABC-B11

  • Calorimeter type
  • Isoperibol
  • Oxygen filling
  • Semi-automatic
  • Bomb volume
  • 282 ml
Automatic Bomb Calorimeter LABC-B10

Automatic Bomb Calorimeter LABC-B10

  • Calorimeter type
  • Isoperibol
  • Oxygen filling
  • Fully automatic oxygen filling & releasing, fully automatic bomb raising & lowering
  • Bomb volume
  • 250 ml
Automatic Bomb Calorimeter LABC-A10

Automatic Bomb Calorimeter LABC-A10

  • Calorimeter type
  • Isoperibol
  • Temperature range
  • 5 to 40°C
  • Measurement range
  • 5 to 40 MJ/ kg

Octane Number & Cetane Number Tester

Octane Number and Cetane Number Tester LOCT-A10

Octane Number and Cetane Number Tester LOCT-A10

  •  Measuring Range For Aviation Gasoline
  • 86.0 to 105.0/MON
  •  Measuring Range For Gasoline For Motor Vehicles
  • National standard: 65.0 to 110.0/RON National-V standard: 70 to 115.0/RON Blended gasoline: 75.0 to 120.0/RON Light gasoline: 50.0 to 85.0 /MON Isomerized gasoline: 85.0 to 120.0/RON Arene gasoline: 90.0 to 120.0/RON
  •  Measuring Range For Ethanol
  • E93: 92.0 to 95.0/RON E97: 95.0 to 99.0/RON Judgement: 60.0 to 120.0/RON
Portable Octane Number and Cetane Meter LOCT-A20

Portable Octane Number and Cetane Meter LOCT-A20

  • Measurement item
  • motor gasoline and diesel
  • measurement unit of octane is ON
  • 40 to 120
  • Permissible error of octane
  • ± 0.5 max

Acid and Alkali Tester

Acid Number Tester LAAT-A12

Acid Number Tester LAAT-A12

  • Measurement range
  • ≥0.05 mg KOH/g
  • Potential measurement range
  • 0 to 1800.0 mV
  • Burette volume
  • 10 mL
Acid Number and Acidity Tester LAAT-A11

Acid Number and Acidity Tester LAAT-A11

  • Ambient temperature
  • ≤ 35 °C
  • Relative humidity
  • ≤ 85 %
  • Precision of titration tube
  • Scale division is 0.02 ml
Water Soluble Acid and Alkali Tester LAAT-A10

Water Soluble Acid and Alkali Tester LAAT-A10

  • Graduated flask
  • 100 ml,50 ml
  • Conical flask
  • 100ml
  • Separatory funnel
  • 250ml
Base Number Tester LAAT-A13

Base Number Tester LAAT-A13

  • Volumetric analysis
  • Titration condensation: 0.1 N; Controlling accuracy: ≤ ± 0.02 ml
  • Automatic acid titration
  • Titration condensation: 0.1 N; Controlling accuracy: ≤ ± 0.1 pH
  • Automatic potential control
  • Titration condensation: 0.1 N; Controlling accuracy: ≤ 10 mV

Aniline Test Equipment

Aniline Point Tester LAPT-A10

Aniline Point Tester LAPT-A10

  • Measurement range
  • Room temperature ~ 150°C
  • Stirring speed
  • 0 ~ 1200 r / min
  • Heating power
  • 25 W
Aniline Point Tester LAPT-A11

Aniline Point Tester LAPT-A11

  • Temperature controlling accuracy
  • ≤ 0.5 ℃
  • Temperature controlling range
  • Room temperature ~ 200 ℃
  • Power supply for illumination
  • 5 V