Labtron LOFP-A10 is designed with higher precision and perfection to meet its wide range of applications. It is incorporated with advanced and reasonable temperature control features.

Thermometer 0 ℃ ~ 360 °C
Scale Division 1 °C
Ambient Temperature ≤ 35 °C
Relative Humidity ≤ 85 %
Outer Crucible-Material Carbon structural steel
Outer Crucible-Diameter Of Upper Opening Φ100 ± 5 mm
Outer Crucible-Height 50 ± 5 mm
Outer Crucible-Diameter Of Bottom Φ56 ± 2 mm
Inner Crucible-Material Carbon structural steel
Inner Crucible-Diameter Of Upper Opening Φ64 ± 1 mm
Inner Crucible-Height 47 ± 1 mm
Inner Crucible-Diameter Of Bottom Φ38± 1 mm
Inner Crucible-Scale Line 12mm away from the rim of upper opening and 18mm away from the rim of upper opening
Gas Tube Φ0.8 ~ Φ1 mm
Flame 3 to 4 mm
Heater Heated by an electric furnace
Heating Power 1000W
Dimensions 410 x 360 x 240 mm
Power Consumption ≤ 1100 W
Power Supply AC 220 V ± 10 %, 50Hz
  • Adjustable heating power
  • Electric current meter to display power
  • Tiny desktop structure
  • Easy to operate
Used to determine the flash point and fire point of lubricating oil and dark petroleum products

Open Cup Flash Point Tester

Automatic COC Flash & Fire Point Tester LOFP-B10

Automatic COC Flash & Fire Point Tester LOFP-B10

  • Ambient Temperature
  • 10 ℃ ~ 40 ℃
  • Relative Humidity
  • ≤ 85 %
  • Temperature Measurement- Full Scale
  • Ambient temperature to ~ 400 ℃
Cleveland Open Cup Flash Point Tester LOFP-A11

Cleveland Open Cup Flash Point Tester LOFP-A11

  • Thermometer
  • 6 ℃ ~ 400 ℃
  • Scale Division
  • 2 °C
  • Spout Aperture
  • 0.6 ~ 0.8 mm
Automatic Cleveland Open Cup Flash Point Tester LOFP-A12

Automatic Cleveland Open Cup Flash Point Tester LOFP-A12

  • Ambient Temperature
  • 10 ℃ ~ 40 °C
  • Relative Humidity
  • ≤ 80 %
  • Temperature Measurement- Full Scale
  • Ambient temperature to 300 °C

Automatic Bomb Calorimeter

Automatic Bomb Calorimeter LABC-B11

Automatic Bomb Calorimeter LABC-B11

  • Calorimeter type
  • Isoperibol
  • Oxygen filling
  • Semi-automatic
  • Bomb volume
  • 282 ml
Automatic Bomb Calorimeter LABC-A10

Automatic Bomb Calorimeter LABC-A10

  • Calorimeter type
  • Isoperibol
  • Temperature range
  • 5 to 40°C
  • Measurement range
  • 5 to 40 MJ/ kg
Automatic Bomb Calorimeter LABC-B10

Automatic Bomb Calorimeter LABC-B10

  • Calorimeter type
  • Isoperibol
  • Oxygen filling
  • Fully automatic oxygen filling & releasing, fully automatic bomb raising & lowering
  • Bomb volume
  • 250 ml
Automatic Bomb Calorimeter LABC-A11

Automatic Bomb Calorimeter LABC-A11

  • Calorimeter type
  • Isoperibol
  • Temperature range
  • 5 to 40°C
  • Measurement range
  • 5 to 40 MJ/ kg

Octane Number & Cetane Number Tester

Portable Octane Number and Cetane Meter LOCT-A20

Portable Octane Number and Cetane Meter LOCT-A20

  • Measurement item
  • motor gasoline and diesel
  • measurement unit of octane is ON
  • 40 to 120
  • Permissible error of octane
  • ± 0.5 max
Octane Number and Cetane Number Tester LOCT-A10

Octane Number and Cetane Number Tester LOCT-A10

  •  Measuring Range For Aviation Gasoline
  • 86.0 to 105.0/MON
  •  Measuring Range For Gasoline For Motor Vehicles
  • National standard: 65.0 to 110.0/RON National-V standard: 70 to 115.0/RON Blended gasoline: 75.0 to 120.0/RON Light gasoline: 50.0 to 85.0 /MON Isomerized gasoline: 85.0 to 120.0/RON Arene gasoline: 90.0 to 120.0/RON
  •  Measuring Range For Ethanol
  • E93: 92.0 to 95.0/RON E97: 95.0 to 99.0/RON Judgement: 60.0 to 120.0/RON

Acid and Alkali Tester

Acid Number and Acidity Tester LAAT-A11

Acid Number and Acidity Tester LAAT-A11

  • Ambient temperature
  • ≤ 35 °C
  • Relative humidity
  • ≤ 85 %
  • Precision of titration tube
  • Scale division is 0.02 ml
Base Number Tester LAAT-A13

Base Number Tester LAAT-A13

  • Volumetric analysis
  • Titration condensation: 0.1 N; Controlling accuracy: ≤ ± 0.02 ml
  • Automatic acid titration
  • Titration condensation: 0.1 N; Controlling accuracy: ≤ ± 0.1 pH
  • Automatic potential control
  • Titration condensation: 0.1 N; Controlling accuracy: ≤ 10 mV
Acid Number Tester LAAT-A12

Acid Number Tester LAAT-A12

  • Measurement range
  • ≥0.05 mg KOH/g
  • Potential measurement range
  • 0 to 1800.0 mV
  • Burette volume
  • 10 mL
Water Soluble Acid and Alkali Tester LAAT-A10

Water Soluble Acid and Alkali Tester LAAT-A10

  • Graduated flask
  • 100 ml,50 ml
  • Conical flask
  • 100ml
  • Separatory funnel
  • 250ml

Aniline Test Equipment

Aniline Point Tester LAPT-A10

Aniline Point Tester LAPT-A10

  • Measurement range
  • Room temperature ~ 150°C
  • Stirring speed
  • 0 ~ 1200 r / min
  • Heating power
  • 25 W
Aniline Point Tester LAPT-A11

Aniline Point Tester LAPT-A11

  • Temperature controlling accuracy
  • ≤ 0.5 ℃
  • Temperature controlling range
  • Room temperature ~ 200 ℃
  • Power supply for illumination
  • 5 V