Labtron LBC-C22 is manufactured with high precision temperature sensor and a high performance A/D converter. The instrument is designed and made as per the International Standards ASTM D5865-13 “Test Methods for Heat of Coal”, ASTM D240-17 “Test Methods for Calorific Value of Petroleum Products” and ASTM D4809-13“Oxygen Bomb Calorimeter”.

Temperature measurement range 10 ~ 35 ℃
Repeatability error ≤ 0.2 % (Grade C)
Endured pressure in oxygen bomb 20 MPa
Operation environment temperature 15 ~ 28 ℃
Temperature resolution 0.001 ℃
Temperature fluctuation Not more than 1 ℃ during a test
Ambient temperature Less than 85 %
Power supply AC 220 V ± 5 %, 50 Hz
  • High precision temperature sensor
  • A high performance A/D converter
  • Automatic and easy operate
It is the desired instrument for power plants, smelting, cement, and petrochemical, scientific research institutes. It is widely used to determine heat value of coal, oils, tar, and paraffin, etc.

Oxygen Bomb Calorimeter

Oxygen Bomb Calorimeter LBC-C21

Oxygen Bomb Calorimeter LBC-C21

  • Temperature controlling range
  • 10 ℃ ~ 35 ℃
  • Temperature resolution
  • 0.001 ℃
  • Mean value of heat capacity
  • 15 kJ / K
Oxygen Bomb Calorimeter LBC-C20

Oxygen Bomb Calorimeter LBC-C20

  • Heat capacity
  • 14000 ~ 15000 J / K
  • Temperature measurement range
  • 10 ~ 35 ℃
  • Repeatability error
  • ≤ 0.2 % (Grade C)

Automatic Bomb Calorimeter

Automatic Bomb Calorimeter LABC-A11

Automatic Bomb Calorimeter LABC-A11

  • Calorimeter type
  • Isoperibol
  • Temperature range
  • 5 to 40°C
  • Measurement range
  • 5 to 40 MJ/ kg
Automatic Bomb Calorimeter LABC-B11

Automatic Bomb Calorimeter LABC-B11

  • Calorimeter type
  • Isoperibol
  • Oxygen filling
  • Semi-automatic
  • Bomb volume
  • 282 ml
Automatic Bomb Calorimeter LABC-A10

Automatic Bomb Calorimeter LABC-A10

  • Calorimeter type
  • Isoperibol
  • Temperature range
  • 5 to 40°C
  • Measurement range
  • 5 to 40 MJ/ kg
Automatic Bomb Calorimeter LABC-B10

Automatic Bomb Calorimeter LABC-B10

  • Calorimeter type
  • Isoperibol
  • Oxygen filling
  • Fully automatic oxygen filling & releasing, fully automatic bomb raising & lowering
  • Bomb volume
  • 250 ml

Octane Number & Cetane Number Tester

Portable Octane Number and Cetane Meter LOCT-A20

Portable Octane Number and Cetane Meter LOCT-A20

  • Measurement item
  • motor gasoline and diesel
  • measurement unit of octane is ON
  • 40 to 120
  • Permissible error of octane
  • ± 0.5 max
Octane Number and Cetane Number Tester LOCT-A10

Octane Number and Cetane Number Tester LOCT-A10

  •  Measuring Range For Aviation Gasoline
  • 86.0 to 105.0/MON
  •  Measuring Range For Gasoline For Motor Vehicles
  • National standard: 65.0 to 110.0/RON National-V standard: 70 to 115.0/RON Blended gasoline: 75.0 to 120.0/RON Light gasoline: 50.0 to 85.0 /MON Isomerized gasoline: 85.0 to 120.0/RON Arene gasoline: 90.0 to 120.0/RON
  •  Measuring Range For Ethanol
  • E93: 92.0 to 95.0/RON E97: 95.0 to 99.0/RON Judgement: 60.0 to 120.0/RON

Acid and Alkali Tester

Base Number Tester LAAT-A13

Base Number Tester LAAT-A13

  • Volumetric analysis
  • Titration condensation: 0.1 N; Controlling accuracy: ≤ ± 0.02 ml
  • Automatic acid titration
  • Titration condensation: 0.1 N; Controlling accuracy: ≤ ± 0.1 pH
  • Automatic potential control
  • Titration condensation: 0.1 N; Controlling accuracy: ≤ 10 mV
Water Soluble Acid and Alkali Tester LAAT-A10

Water Soluble Acid and Alkali Tester LAAT-A10

  • Graduated flask
  • 100 ml,50 ml
  • Conical flask
  • 100ml
  • Separatory funnel
  • 250ml
Acid Number and Acidity Tester LAAT-A11

Acid Number and Acidity Tester LAAT-A11

  • Ambient temperature
  • ≤ 35 °C
  • Relative humidity
  • ≤ 85 %
  • Precision of titration tube
  • Scale division is 0.02 ml
Acid Number Tester LAAT-A12

Acid Number Tester LAAT-A12

  • Measurement range
  • ≥0.05 mg KOH/g
  • Potential measurement range
  • 0 to 1800.0 mV
  • Burette volume
  • 10 mL

Aniline Test Equipment

Aniline Point Tester LAPT-A11

Aniline Point Tester LAPT-A11

  • Temperature controlling accuracy
  • ≤ 0.5 ℃
  • Temperature controlling range
  • Room temperature ~ 200 ℃
  • Power supply for illumination
  • 5 V
Aniline Point Tester LAPT-A10

Aniline Point Tester LAPT-A10

  • Measurement range
  • Room temperature ~ 150°C
  • Stirring speed
  • 0 ~ 1200 r / min
  • Heating power
  • 25 W