Coulometric Karl Fischer Titrator LWT-A30 is a benchtop unit with 10°C to 35°C ambient temperature range, 0 to 100 mg measurement range, and 10 µg to 1000 µg, ± 2 µg amount of electrolysed water range. Features fast and accurate water content determination with very simple process and portable handling unit. It is in accordance with ASTM D1533 (Standard Test Method for Water in Insulating Liquids by Coulometric Karl Fischer Titration) and ASTM D6304 (Standard Test Method for Determination of Water in Petroleum Products, Lubricating Oils, and Additives by Coulometric Karl Fischer Titration).

Ambient Temperature 10°C to 35°C
Measurement Range 0 to 100 mg
Resolution 0.1 µg
Max. Electrolysis Speed 40 µg /s
Amount and Precision of electrolysed water 10 µg to 1000 µg, ± 2 µg and >1000 µg, 0.2 %
Relative Humidity ≤ 85 %
Max. Power Consumption 30 W
Power Supply AC 220 V ± 20 %, 50 Hz
Dimension 320 × 240 × 150 mm
Net Weight 5 kg
  • Capability of saving maximum 255 data
  • 240 × 128 pixels dot-matrix LCD screen
  • Equipped with Calendar clock, to record date and time
  • End point of sample is measured with high electrode precision value with electrolyte blank current and equilibrium point drift compensation adaptation for accurate measurement
  • Automatic shutdown LCD screen with screen protection function
  • Design with open-circuit fault and short-circuit fault for automatic detecting function of measuring electrode
  • Portable and easy handling
Coulometric Karl Fischer Titrator is used for the determination of water content in petroleum products and lubricating oils and additives by Karl Fischer titration

Water Content Tester

Water Content Tester LWT-A10

Water Content Tester LWT-A10

  • Ambient Temperature
  • ≤ 35 °C
  • Relative Humidity
  • ≤ 85 %
  • Heating Power of Electric Furnace
  • 1000 W
Coulometric Karl Fischer Titrator LWT-A31

Coulometric Karl Fischer Titrator LWT-A31

  • Maximum current
  • 400 mA
  • Measurement range
  • 3 µg to 9999.9 µg
  • Resolution
  • 0.1 µg
Water Content Tester LWT-A11

Water Content Tester LWT-A11

  • Ambient Temperature
  • ≤ 35 °C
  • Relative Humidity
  • ≤85 %
  • Heating Power of Electric Furnace
  • 1000 W × 2
Crude Petroleum Water Content Tester LWT-B10

Crude Petroleum Water Content Tester LWT-B10

  • Ambient Temperature
  • (-10) °C ~ 35 °C
  • Relative Humidity
  • ≤ 85 %
  • Distillation flask
  • 1000 ml

Automatic Bomb Calorimeter

Automatic Bomb Calorimeter LABC-A10

Automatic Bomb Calorimeter LABC-A10

  • Calorimeter type
  • Isoperibol
  • Temperature range
  • 5 to 40°C
  • Measurement range
  • 5 to 40 MJ/ kg
Automatic Bomb Calorimeter LABC-B11

Automatic Bomb Calorimeter LABC-B11

  • Calorimeter type
  • Isoperibol
  • Oxygen filling
  • Semi-automatic
  • Bomb volume
  • 282 ml
Automatic Bomb Calorimeter LABC-A11

Automatic Bomb Calorimeter LABC-A11

  • Calorimeter type
  • Isoperibol
  • Temperature range
  • 5 to 40°C
  • Measurement range
  • 5 to 40 MJ/ kg
Automatic Bomb Calorimeter LABC-B10

Automatic Bomb Calorimeter LABC-B10

  • Calorimeter type
  • Isoperibol
  • Oxygen filling
  • Fully automatic oxygen filling & releasing, fully automatic bomb raising & lowering
  • Bomb volume
  • 250 ml

Octane Number & Cetane Number Tester

Portable Octane Number and Cetane Meter LOCT-A20

Portable Octane Number and Cetane Meter LOCT-A20

  • Measurement item
  • motor gasoline and diesel
  • measurement unit of octane is ON
  • 40 to 120
  • Permissible error of octane
  • ± 0.5 max
Octane Number and Cetane Number Tester LOCT-A10

Octane Number and Cetane Number Tester LOCT-A10

  •  Measuring Range For Aviation Gasoline
  • 86.0 to 105.0/MON
  •  Measuring Range For Gasoline For Motor Vehicles
  • National standard: 65.0 to 110.0/RON National-V standard: 70 to 115.0/RON Blended gasoline: 75.0 to 120.0/RON Light gasoline: 50.0 to 85.0 /MON Isomerized gasoline: 85.0 to 120.0/RON Arene gasoline: 90.0 to 120.0/RON
  •  Measuring Range For Ethanol
  • E93: 92.0 to 95.0/RON E97: 95.0 to 99.0/RON Judgement: 60.0 to 120.0/RON

Acid and Alkali Tester

Water Soluble Acid and Alkali Tester LAAT-A10

Water Soluble Acid and Alkali Tester LAAT-A10

  • Graduated flask
  • 100 ml,50 ml
  • Conical flask
  • 100ml
  • Separatory funnel
  • 250ml
Base Number Tester LAAT-A13

Base Number Tester LAAT-A13

  • Volumetric analysis
  • Titration condensation: 0.1 N; Controlling accuracy: ≤ ± 0.02 ml
  • Automatic acid titration
  • Titration condensation: 0.1 N; Controlling accuracy: ≤ ± 0.1 pH
  • Automatic potential control
  • Titration condensation: 0.1 N; Controlling accuracy: ≤ 10 mV
Acid Number Tester LAAT-A12

Acid Number Tester LAAT-A12

  • Measurement range
  • ≥0.05 mg KOH/g
  • Potential measurement range
  • 0 to 1800.0 mV
  • Burette volume
  • 10 mL
Acid Number and Acidity Tester LAAT-A11

Acid Number and Acidity Tester LAAT-A11

  • Ambient temperature
  • ≤ 35 °C
  • Relative humidity
  • ≤ 85 %
  • Precision of titration tube
  • Scale division is 0.02 ml

Aniline Test Equipment

Aniline Point Tester LAPT-A11

Aniline Point Tester LAPT-A11

  • Temperature controlling accuracy
  • ≤ 0.5 ℃
  • Temperature controlling range
  • Room temperature ~ 200 ℃
  • Power supply for illumination
  • 5 V
Aniline Point Tester LAPT-A10

Aniline Point Tester LAPT-A10

  • Measurement range
  • Room temperature ~ 150°C
  • Stirring speed
  • 0 ~ 1200 r / min
  • Heating power
  • 25 W