Angular Spectrometer LASM-A10 is a tabletop unit, offers angle measurement accuracy of 1 inch and diopter compensation range of ≥ ± 5 diopters. Incorporated with two verniers at the opposite edges, to remove errors induced by the off center errors of the divided circle and thrusting bearing under the divided circle for smooth rotation. Equipped with magnifier with handle, optical parallel plate and planar holographic grating. Built in with adjustable dioptre, moveable telescopes eyepiece and adjustable stage.

Angle Measurement Accuracy 1inch
Optical Parameter <table class='table table-striped table-bordered table-responsive'><tr><td><strong>Focal Length</strong></td><td>170 mm</td></tr><tr><td><strong>Effective Aperture</strong></td><td>Φ 22 mm</td></tr><tr><td><strong>Field of View</strong></td><td>3° 22inch</td></tr><tr><td><strong>Focal Length of Telescope’s Eyepiece</strong></td><td>24.3 mm</td></tr><tr><td><strong>Maximum Length Between Collimator and Telescope</strong></td><td>120 mm</td></tr><tr><td><strong>Slit Width</strong></td><td>0.02 to 2 mm</td></tr><tr><td><strong>Diopter Compensation Range</strong></td><td>≥ ± 5 diopters</td></tr></table>
Divided Circle <table class='table table-striped table-bordered table-responsive'><tr><td><strong>Diameter</strong></td><td>Φ178 mm</td></tr><tr><td><strong>Circle Graduation</strong></td><td>0° to 360°</td></tr><tr><td><strong>Division</strong></td><td>0.5°</td></tr><tr><td><strong>Vernier Reading Value</strong></td><td>1inch</td></tr></table>
Stage <table class='table table-striped table-bordered table-responsive'><tr><td><strong>Diameter</strong></td><td>Φ70 mm</td></tr><tr><td><strong>Rotating Range</strong></td><td>360°</td></tr><tr><td><strong>Range of Vertical Adjustment</strong></td><td>20 mm</td></tr></table>
Attachments <table class='table table-striped table-bordered table-responsive'><tr><td><strong>Prism Angle</strong></td><td>60° ± 5inch</td></tr><tr><td><strong>Transformer</strong></td><td>6.3 Ⅴ/220 Ⅴ (3 ⅤA)</td></tr><tr><td><strong>Planar Holographic Grating</strong></td><td>300/ mm</td></tr></table>
Dimensions (W×D×H) 251×518×250 mm
Net Weight 11.8 kg
  • Highly efficient and safe with complete functions
  • Easy to clean, corrosion resistant, stainless steel lining
  • Compact and space saving design
  • Easy to use, operate and less maintenance
  • Built in with fine adjusting knob of telescope, collimator unit and brake mount
Angular Spectrometer is widely used for angular measurements based on polarization, diffraction, refraction and interference. It is commonly used in color measurements, concentration determination of chemical components and electromagnetic radiation analysis.

Angular Spectrometer

FTIR Spectrometer

FTIR Spectrometer LIR-B10

FTIR Spectrometer LIR-B10

  • Spectral Range
  • 7800 cm-1 to 350 cm-1
  • Resolution
  • 0.85 cm-1
  • Wave number precision
  • ± 0.01 cm-1

Atomic Fluorescence Spectrometer

Atomic Fluorescence Spectrometer LAFS-A10

Atomic Fluorescence Spectrometer LAFS-A10

  • Beam Configuration
  • Dual Channel
  • Elements ( Measuring Range )
  • As, Se, Pb, Bi, Sb, Te, Sn< 0.01 µg/LHg, Cd< 0.001 µg/LZn< 1.0 µg/LGe< 0.1 µg/L
  • Precision ( RSD )
  • < 1.0

ICP Spectrometer

ICP spectrometer LICP-A10

ICP spectrometer LICP-A10

  • Wavelength range ( 3600 lines / mm )
  • 180 to 500 nm
  • Wavelength range ( 2400 lines / mm )
  • 180 to 800 nm
  • Temperature
  • 20 ~ 28 °C
ICP Spectrometer LICP-A12

ICP Spectrometer LICP-A12

  • Wavelength range
  • 195 to 800 mm
  • Elements per minute
  • 10 elements
  • Temperature range
  • 32 °C
ICP Spectrometer LICP-A11

ICP Spectrometer LICP-A11

  • Wavelength range
  • 180 to 900 nm
  • Elements per minute
  • 15 elements
  • Temperature
  • 29 °C
ICP Spectrometer LICP-B10

ICP Spectrometer LICP-B10

  • Monochromator Specifications
  • Optical typeCzerny turnerResolution≤ 0.015nm (3600 line grating) ≤ 0.030nm (2400 line grating)Focal length1000 mmGrating specificationshuge holographic grating with 3600 L/mil or 2400 L/mil and 80 mm × 100 mm of ruling areaWavelength range195 to 500 nm for 3600 line grating 195 to 800 nm for 2400 line grating
  • Solid State Power Specifications
  • Frequency27.12 MHz Frequency stability: < 0.05%Spray chamberScott double pass spray chamberOutput power800 W to 1600 W, adjustable with power efficiency more than 65%Output power stability≤ 0.05%Induction coil25 mm × 3 ID (ID-internal diameter), equipped with three concentric quartz torch tubes 35 mm ED (ED-external diameter)
  • Technical Specifications
  • Suitable sample content rangeLiquid sample: 0.01 ppm to several thousand ppm Solid or power sample: 0.001% to 70%Repeatabilityshort-term stability- RSD ≤ 1.5% Long-term stability: RSD ≤ 2%Test speed5 to 8 elements / minLimits of detection (LOD, µg/L) for most elements1ppb to 10ppb

XRF Spectrometer

Handheld XRF Spectrometer LXRF-B10

Handheld XRF Spectrometer LXRF-B10

  • Analytical Method
  • Energy dispersive X-ray fluorescence analytical Method
  • Elements Measuring
  • Atomic number from 12 to 92 [elements from magnesium (Mg) to uranium (U)] can be measured
  • Range
  • Simultaneous detector
XRF-Spectrometer LXRF-A10

XRF-Spectrometer LXRF-A10

  • Measureable elements
  • S to U
  • Detection limit
  • 1 ppm
  • Temperature
  • 15 ~ 30 °C
Handheld XRF Spectrometer LXRF-B11

Handheld XRF Spectrometer LXRF-B11

  • Analytical Method
  • Energy dispersive X-ray fluorescence analytical Method
  • Elements Measuring
  • Atomic number from 12 to 92 [elements from magnesium (Mg) to uranium (U)] can be measured
  • Range
  • Simultaneous detector