Visible spectrophotometer comes with large memory space which can store multiple sets of data. It comes with monolithic, microprocessor controlled LCD display of 128 × 64 bit. In this vis-spectrophotometer standard curve for quantitative measurement can be established in simple method. Quantitative measurement of standard curve is established through direct input of K & B factor. It is useful in scientific research and industries for detection of impurities and other elements.

Wavelength Range 325 ~ 1000 nm
Setting Wavelength Automatic
Spectral Bandwidth 2 nm
Wavelength Accuracy ± 1.0 nm
Wavelength Repeatability ≤ 0.2 nm
Photometric Range (-0.3) ~ 3 A
Photometric Accuracy ± 0.3 % T
Photometric Repeatability 0.15 % τ
Detector Import Silicon Photodiode Detector
Light Source Import Tungsten Lamp
Stray Light ≤ 0.05 % τ
Stability 0.001 A / h at 500 nm
Power Requirement AC 220 V / 50 Hz, 110 V / 60 Hz.
Dimensions 460 × 330 × 210 mm
Weight 11 kg
Power 120 W
  • Wavelength range of 325 ~ 1000 nm
  • Automatic zero, 100 % and wavelength adjustment
  • Equipped with Single-chip microcomputer control
  • Large LCD display with 128 × 64 bit
  • Large sample cell(~ 5 mm to 100 mm)
  • Colour filter automatic switching
  • More precise measurement
  • Imported Silicon Photodiode Detector and USB interface
It is useful in scientific research and industries for quantitative and qualitative analysis, detection of impurities and functional groups determination.

Visible Spectrophotometer

Labtron provides extensive range of visible spectrophotometer LVS series which can operate over a wavelength range of 320-1100nm. It brings unmatched performance with outstanding accuracy and precision.

Vis Spectrophotometer LVS-A10

Vis Spectrophotometer LVS-A10

  • Wavelength Range
  • 330 to 1000 nm
  • Spectral Bandwidth
  • 5 nm
  • Wavelength Accuracy
  • ± 2 nm
Vis Spectrophotometer LVS-C10

Vis Spectrophotometer LVS-C10

  • Wavelength Range
  • 320 ~ 1100 nm
  • Spectral Bandwidth
  • 4 nm
  • Wavelength Accuracy
  • ± 0.5 nm
Vis Spectrophotometer LVS-A11

Vis Spectrophotometer LVS-A11

  • Wavelength Range
  • 335 ~ 1000 nm
  • Spectral Bandwidth
  • 4 nm
  • Wavelength Accuracy
  • ± 2 nm
Vis Spectrophotometer LVS-C11

Vis Spectrophotometer LVS-C11

  • Wavelength Range
  • 320 ~ 1000 nm
  • Spectral Bandwidth
  • 2 nm
  • Wavelength Accuracy
  • ± 0.5 nm

Double Beam UV/Vis Spectrophotometer

Our range of Double Beam UV/VIS spectrophotometers offer long optical path which ensure high accuracy and stability. Its design measures the transmittance of the sample and solvent simultaneously. It is highly precise and performs powerful analysis.

Double Beam UV/Vis Spectrophotometer LUS-B30

Double Beam UV/Vis Spectrophotometer LUS-B30

  • Wavelength range
  • 190 to 1100 nm
  • Spectral bandwidth
  • 2 nm
  • Wavelength Accuracy
  • ± 0.1nm @ 656.1 nm, ± 0.3 nm @ all
Double Beam UV-Vis Spectrophotometer LUS-B13

Double Beam UV-Vis Spectrophotometer LUS-B13

  • Wavelength Range
  • 190 to 1100 nm
  • Spectral Bandwidth
  • 1.0 nm
  • Optical System
  • Double beam
Double beam UV-Visible Spectrophotometer LUS-B14

Double beam UV-Visible Spectrophotometer LUS-B14

  • Wavelength range
  • 190 ~ 1100 nm
  • Spectral bandwidth
  • 1.8 nm
  • Wavelength accuracy
  • ± 0.3 nm
Double Beam UV-Vis Spectrophotometer LUS-B40

Double Beam UV-Vis Spectrophotometer LUS-B40

  • Wavelength range
  • 190 to 1100 nm
  • Spectral bandwidth
  • 0.5/1/2/4 nm
  • Wavelength Accuracy
  • ± 0.1nm (D2, 656.1 nm), ± 0.3 nm full range

Nano Spectrophotometer

We produce a wide range of Nano spectrophotometer for qualitative and quantitative analysis of DNA/RNA in the sample. Our product is highly sensitive and requires only 0.5-2µl of sample for analysis.

Nano Spectrophotometer LNS-A20

Nano Spectrophotometer LNS-A20

  • Wavelength range
  • 190 to 850 nm
  • Wavelength accuracy
  • ± 1 nm
  • Wavelength Resolution
  • 2 nm (FWHM at Hg 546 nm)
Nano Spectrophotometer LNS-A10

Nano Spectrophotometer LNS-A10

  • Wavelength range
  • 200 - 800 nm
  • Path length
  • 0.2 mm (For high concentration measurement); 1.0 mm (For ordinary)
  • Wavelength accuracy
  • ± 1 nm
Nano Spectrophotometer LNS-C11

Nano Spectrophotometer LNS-C11

  • Cuvette
  • Yes
  • PC
  • Inbuilt
  • Wavelength range
  • 190 - 850 nm
Nano Spectrophotometer LNS-A21

Nano Spectrophotometer LNS-A21

  • Wavelength range
  • 200 - 850 nm
  • Path length
  • 1 mm, 2 mm, 5 mm, 10 mm
  • Wavelength accuracy
  • ± 1 nm

Single Beam UV/Visible Spectrophotometer

We manufacture highly precise UV/Vis automatic scanning spectrophotometer with wavelength ranging from 190-1100nm. It can perform quantitative measurement, photometric measurement, spectrum scanning, DNA/Protein analysis. It is in demand for its user-friendly operations

Single Beam UV/Vis Spectrophotometer LUS-A51

Single Beam UV/Vis Spectrophotometer LUS-A51

  • Wavelength range
  • 190 to 1100 nm
  • Spectral bandwidth
  • 1 nm
  • Wavelength Accuracy
  • ± 0.1nm @ 656.1 nm, ± 0.3 nm @ all
Single Beam UV/Visible Spectrophotometer LUS-A30

Single Beam UV/Visible Spectrophotometer LUS-A30

  • Wavelength Range
  • 190 ~ 1100 nm
  • Setting Wavelength
  • Automatic
  • Spectral Bandwidth
  • 4 nm
Single Beam UV/Vis Spectrophotometer LUS-A50

Single Beam UV/Vis Spectrophotometer LUS-A50

  • Wavelength range
  • 190 to 1100 nm
  • Spectral bandwidth
  • 2 nm
  • Wavelength Accuracy
  • ± 0.1nm @ 656.1 nm, ± 0.3 nm @ all
Single Beam UV/Vis Spectrophotometer LUS-A52

Single Beam UV/Vis Spectrophotometer LUS-A52

  • Wavelength range
  • 190 to 1100 nm
  • Spectral bandwidth
  • 0.5/1/2/4/5 nm
  • Wavelength Accuracy
  • ± 0.1nm @ 656.1 nm, ± 0.3 nm @ all

Atomic Absorption Spectrophotometer

Labtron Atomic Absorption Spectrophotometer makes use of the modern in technology. It is acquired after thorough research into the desires of the diagnostic community. It has all the power, performance and speed necessitated in today’s modern laboratory.

Atomic Absorption Spectrophotometer LAAS-A22

Atomic Absorption Spectrophotometer LAAS-A22

  • Wavelength range
  • 180 – 900 nm
  • Spectral Bandwidth
  • 0.1 nm,0.2 nm,0.4 nm, 1.0 nm, 2.0 nm automatic setting
  • Wavelength accuracy
  • ≤ 0.15 nm
Atomic Absorption Spectrophotometer LAAS-A10

Atomic Absorption Spectrophotometer LAAS-A10

  • Monochromator
  • Czerny-Turner
  • Wavelength range
  • 190 – 900 nm
  • Spectral Bandwidth
  • 0.2,0.4,1.0,2.0 nm, multi-speed automatic switching
Flame Atomic Absorption Spectrophotometer LAAS-A12

Flame Atomic Absorption Spectrophotometer LAAS-A12

  • Wavelength range
  • 190 nm ~ 900 nm
  • Spectral bandwidth
  • 0.1 nm, 0.2 nm, 1.0 nm, 2.0 nm
  • Wavelength accuracy
  • ± 0.25 nm
Atomic Absorption Spectrophotometer LAAS-A11

Atomic Absorption Spectrophotometer LAAS-A11

  • Wavelength range
  • 190 - 900 nm
  • Spectral Bandwidth
  • 0.2 nm, 0.4 nm, 0.7 nm, 1.4 nm, 2.4 nm, 5.0 nm
  • Wavelength accuracy
  • ≤ ± 0.5 nm