We deliver an excellent range of UV Test chambers, the model of LUVC-A10 features three types of UV lamps: UV-A lamp that can simulate sunlight from 365 nm to 295 nm cut-off wavelength, UV-B lamp that can simulate short wavelength UV radiation that reaches earth’s surface, UV-C lamp that can simulate UV sunlight through windows, this provides an accurate environment condition to give precise test results.

UV Temperature 50 °C to 75 °C
Testing Capacity 48 piece (75 x 150 mm); 50 piece (75x 150 mm)
Weight 136 kg
Water Consumption Distilled water, 8liters per day
Dimension(W x D x H) 137 x 53 x 136 cm
Power 1ψ, 120 V / 60 Hz, 16 A or 230 V / 50 Hz, 9 A, 1800 W(max)
  • Designed to perform UV light testing with the help of UV lamps
  • Provision to choose among different wavelengths of UV light
  • Three types of UV lamps: UV-A lamp can simulate sunlight from 365 nm to 295 nm cut-off wavelength, UV-B lamp can simulate short wavelength UV radiation that reaches earth’s surface, UV-C lamp can simulate UV sunlight through windows
  • Light and temperature can be controlled through an user friendly coloured touch screen
  • Light intensity control system allow users to set different test light intensity based on test requirements
The UV Test Chamber is widely used in plastics, printing and packaging, paint, resins, adhesives, automotive, cosmetics, metals, electroplating, medicine, etc.

UV Test Chamber

We manufacture UV test machine to simulate sunlight alongwith condenser and water spray system to simulate rain and dew. These chambers are used in various industries to detect the damage caused by environmental factors.

UV Test Chamber LUVC-A20

UV Test Chamber LUVC-A20

  • Temperature Range
  • RT + 100 °C ~ 850 °C
  • Humidity range
  • At 400 °C: R.H. is 40 % ~ 85 % / At 800 °C: R.H. is 30 % ~ 50 %
  • Testing Time
  • 20 hours
UV Test Chamber LUVC-A21

UV Test Chamber LUVC-A21

  • Temperature Range
  • RT + 100 °C ~ 630 °C
  • Humidity range
  • 30 % ~ 85 % RH
  • Testing Time
  • 20 hours

Drug Test Chamber

Drug test chambers are designed to conduct stability and shelf life studies on drug and drugs components.

Drug Stability Chamber with Illumination LDST-B12

Drug Stability Chamber with Illumination LDST-B12

  • Volume
  • 500 L
  • Temperature Range(without illumination)
  • 0 - 65 °C
  • Temperature Range(with illumination)
  • 10 °C - 65°C
Drug Stability Test Chamber LDST-A12

Drug Stability Test Chamber LDST-A12

  • Volume
  • 500 L
  • Temperature Range
  • 0 - 65 °C
  • Temperature Fluctuation
  • ± 0.5 °C
Drug Stability Test Chamber LDST-A22

Drug Stability Test Chamber LDST-A22

  • Interior Volume
  • 500 L
  • Heat load
  • 1000 W
  • Temperature Range
  • 0℃ to 100 ℃
Drug Stability Test Chamber LDST-A24

Drug Stability Test Chamber LDST-A24

  • Interior Volume
  • 1000 L
  • Heat load
  • 1000 W
  • Temperature Range
  • 0℃ to 100 ℃

Ozone Test Chamber

Labtron offers ozone test chambers which can simulate ozone atmospheric conditions to be used for aging cracking test of non-metal materials and rubber products, to determine the anti-ozone properties of the products.

Ozone Test Chamber LOC-A14

Ozone Test Chamber LOC-A14

  • Diameter of holder (mm)
  • 900
  • Length of each side (mm)
  • 460
  • Temperature range
  • 0℃ ~ 100℃
Ozone Test Chamber LOC-A11

Ozone Test Chamber LOC-A11

  • Diameter of holder (mm)
  • 400
  • Length of each side (mm)
  • 180
  • Temperature range
  • 0℃ ~ 100℃
Ozone Test Chamber LOC-A13

Ozone Test Chamber LOC-A13

  • Diameter of holder (mm)
  • 700
  • Length of each side (mm)
  • 350
  • Temperature range
  • 0℃ ~ 100℃
Ozone Test Chamber LOC-A12

Ozone Test Chamber LOC-A12

  • Diameter of holder (mm)
  • 600
  • Length of each side (mm)
  • 220
  • Temperature range
  • 0℃ ~ 100℃

Plant Growth Chamber

Labtron’s plant growth chamber is designed with accurate control of temperature, light, humidity, CO2 and other environmental factors which are necessary for plant growth. These chambers are helpful for researchers to carryout different experiments on plants without any dependency on climatic factors.

Plant Growth Chamber LPGC-B14

Plant Growth Chamber LPGC-B14

  • Chamber Volume
  • 1000 L
  • Shelves
  • 3(PCS)
  • Display Resolution
  • 0.1 ℃
Plant Growth Chamber LPGC-A11

Plant Growth Chamber LPGC-A11

  • Chamber Volume
  • 450 L
  • Shelves
  • 3(PCS)
  • Display Resolution
  • 0.1 ℃
Plant Growth Chamber LPGC-B12

Plant Growth Chamber LPGC-B12

  • Chamber Volume
  • 450 L
  • Shelves
  • 3(PCS)
  • Display Resolution
  • 0.1 ℃
Plant Growth Chamber LPGC-A13

Plant Growth Chamber LPGC-A13

  • Chamber Volume
  • 1000 L
  • Shelves
  • 3(PCS)
  • Display Resolution
  • 0.1 ℃

Salt Spray Test Chamber

Labtron offers wide range of salt spray corrosion test systems with ability to test the corrosive resistant of products. Our user friendly products suit our clients' requirement and hence, continue to be in demand.

Salt Spray Test Chamber LSSC-A15

Salt Spray Test Chamber LSSC-A15

  • Testing room capacity
  • 1600 L
  • Temperature range
  • Ambient to +60°C
  • Humidity range
  • 95% to 98% RH
Salt Spray Test Chamber LSSC-A14

Salt Spray Test Chamber LSSC-A14

  • Testing room capacity
  • 1030 L
  • Temperature range
  • Ambient to +60°C
  • Humidity range
  • 95% to 98% RH
Salt Spray Test Chamber LSSC-A12

Salt Spray Test Chamber LSSC-A12

  • Testing room capacity
  • 410 L
  • Temperature range
  • Ambient to +60°C
  • Humidity range
  • 95 to 98% RH
Salt Spray Test Chamber LSSC-A10

Salt Spray Test Chamber LSSC-A10

  • Testing room capacity
  • 110 L
  • Temperature range
  • Ambient to +60°C
  • Humidity range
  • 95 to 98% RH