Water Purification System LWPS-A11 mainly consists of two stages of water quality and its feed water is tap water. It follows type III and type I systems. Features pretreatment system, RO system, ultrapure water system conveying unit and control system. Fully automatic control over the whole process, e.g. automatic water preparation, when water tank is full, automatically stop the system and cut off the power and water. Built-in RO membrane timing automatic flush procedures, and manual RO membrane cleaning button is available.

Water quality Two stage(Type III and type I)
Feed water Tap waterTDS≤400ppm<hr> Water temperature: 5-40℃<hr> Type 3 water ≥10L/h
Conectivity <5 μs/cm@25℃
Resistivity 18.25 MΩ.cm @ 25 ℃
TOC < 5ppb
Bacteria < 0.1 cfu/ml
Endotoxin < 0.001 EU/ml
Particle ( > 0.22μm) <1/ml
Absorbance (254nm,1cm optical distance) < 0.001 EU/ml
Reactive Silica(SiO2) < 0.01 ppm
RNases < 0.01 ng/ml
DNases < 4 pg/μl
Temperature 5 ℃ ~ 40 ℃
Humidity 10 % ~ 80 %
Water production rate Type 1 water flow rate: 1-1.5L/min
Micro filtration Millipore Millipak 0.22μm membrane or hollowed fiber membrane filter
Power supply 230 V/50 Hz 150 W
Main body Dimension (L × W × H) 340 × 550 × 530 mm (bench type)
  • Millipore BioPak UF membrane to reduce the pyrogen, RNase, DNase
  • Ultra-purification system: Millipore ion exchange resin cartridge and special flow design, high ultra-purify efficiency
  • Effectively remove the trace ions in water; guarantee the stability of water quality
  • Micro filtration: Making the particles content (larger than 0.22μm) is
  • Built-in manual water cycling program and ultrapure water auto-cycle program to keep the water quality of ultrapure water
  • Water resistance on-line monitoring, realizing man-machine conversation
  • System can be installed on the lab bench
  • 30L PE water reservoir with vent valve
Used for Medical device injection to human body, DNA/RHA preparation, DNA testing, HPLC (test and analysis of amino acid, penicillin; Organic ingredients), GCMS, ICP, IC, gas chromatography, AAS etc.

Water Purification System (Feed-specific)

Water Purification System LWPS-C11

Water Purification System LWPS-C11

  • Output 2nd stage RO water
  • 90 liters/hour
  • Output ultrapure water
  • Up to 2 liters/minute (when tank is full)
  • Ultrapure Water Quality
  • Resistivity (25°C) 18.2 M Ω cm TOC: < 3ppb Bacteria: 0.2 µm):
Water Purification System LWPS-A10

Water Purification System LWPS-A10

  • Water quality
  • One stage (Type I)
  • Feed water
  • RO water /Distilled water Water temperature: 5 ~ 40℃
  • Resistivity
  • 18.25 MΩ.cm @ 25 ℃
Water Purification System LWPS-C10

Water Purification System LWPS-C10

  • Output 2nd stage RO water
  • 90 liters/hour
  • Output ultrapure water
  • Up to 2 liters/minute (when tank is full)
  • Ultrapure Water Quality
  • Resistivity (25°C) 18.2 M Ω cm TOC: < 3ppb Bacteria: 0.2 µm):

Type I and Type III Water Purification System

This water purification system is a combinational system that produces Type III water after RO and Type I water after deionization in one cycle

Type I and Type III RO Water Purification System LOTW-B11

Type I and Type III RO Water Purification System LOTW-B11

  • Output of Pure water
  • &ge; 20 L / hr.
  • Water Type
  • Type I and Type III
  • Water Tank capacity
  • 30 L
Type I and Type III RO Water Purification System LOTW-B12

Type I and Type III RO Water Purification System LOTW-B12

  • Output of Pure water
  • &ge; 30 L / hr.
  • Water Type
  • Type I and Type III
  • Water Tank capacity
  • 30 L
Type I and Type III RO Water Purification System LOTW-A11

Type I and Type III RO Water Purification System LOTW-A11

  • Output of Pure water
  • &ge; 20 L / hr.
  • Water Type
  • Type I and Type III
  • Water Tank capacity
  • 30 L
Type I and Type III RO Water Purification System LOTW-A12

Type I and Type III RO Water Purification System LOTW-A12

  • Output of Pure water
  • &ge; 30 L / hr.
  • Water Type
  • Type I and Type III
  • Water Tank capacity
  • 30 L

Type II Water Purification System

This water purification system provides Type II level water with consistency and reliability. It removes approximately 98% of inorganic ions and 99 % of all dissolved organic substances

Type II Water Purification System LTWP-A12

Type II Water Purification System LTWP-A12

  • Output of Pure water
  • &ge; 30 L / hr.
  • Process
  • Single Pass RO system
  • Water Type
  • Type II
Type II Water Purification System LTWP-A11

Type II Water Purification System LTWP-A11

  • Output of Pure water
  • &ge; 20 L / hr.
  • Process
  • Single Pass RO system
  • Water Type
  • Type II
Type II Water Purification System LTWP-A13

Type II Water Purification System LTWP-A13

  • Output of Pure water
  • &ge; 40 L / hr.
  • Process
  • Single Pass RO system
  • Water Type
  • Type II
Type II Water Purification System LTWP-B10

Type II Water Purification System LTWP-B10

  • Output of Pure water
  • &ge; 10 L / hr.
  • Process
  • Double Pass RO system
  • Water Type
  • Type II

Type III Water Purification System

It provides Type III level water which is required for chemical and physical inspection or for washing lab glassware’s

Type III Water Purification System LHWP-B12

Type III Water Purification System LHWP-B12

  • Output of Pure water
  • &ge; 30 L / hr.
  • Water Type
  • Type III
  • Configuration
  • Benchtop
Type III Water Purification System LHWP-B10

Type III Water Purification System LHWP-B10

  • Output of Pure water
  • &ge; 10 L / hr.
  • Water Type
  • Type III
  • Configuration
  • Benchtop
Type III Water Purification System LHWP-B14

Type III Water Purification System LHWP-B14

  • Output of Pure water
  • &ge; 50 L / hr.
  • Water Type
  • Type III
  • Configuration
  • Floor Standing
Type III Water Purification System LHWP-A10

Type III Water Purification System LHWP-A10

  • Output of Pure water
  • &ge; 10 L / hr.
  • Water Type
  • Type III
  • Configuration
  • Benchtop

Radio Frequency Identification Water Purification System

Radio Frequency Identification Water Purifier are equipped with a RFID Radio Frequency Identification Chip which helps keeping a check on the quality of water in real time. This helps in monitoring of parameters for the purifier

Radio Frequency Identification Water Purification System LRFW-B11

Radio Frequency Identification Water Purification System LRFW-B11

  • Output of Pure water
  • &ge; 20 L / hr.
  • Process
  • Double Pass RO system
  • Configuration
  • Benchtop
Radio Frequency Identification Water Purification System LRFW-B12

Radio Frequency Identification Water Purification System LRFW-B12

  • Output of Pure water
  • &ge; 30 L / hr.
  • Process
  • Double Pass RO system
  • Configuration
  • Benchtop
Radio Frequency Identification Water Purification System LRFW-C10

Radio Frequency Identification Water Purification System LRFW-C10

  • Feed Water
  • Tap Water , TDS ≤ 400 ppm, Water Temperature: 5 to 40°C
  • Water Production Rate
  • ≥ 10 L/ h, Ultrapure Water Flow Rate 2 L/ min
  • Water Quality (Two Stage)
  • Ultrapure water: Resistivity: 18.25 MΩ.cm at 25°C conforms to ASTM CAP NCCLS
Radio Frequency Identification Water Purification System LRFW-A11

Radio Frequency Identification Water Purification System LRFW-A11

  • Output of Pure water
  • &ge; 20 L / hr.
  • Process
  • Single Pass RO system
  • Configuration
  • Benchtop