Digital low load Vickers Hardness tester TDVH-A10 comes with large LCD screen to display the parameters like test mode, test pressure, indention length, hardness values, pressure holding time and number of test for study. Equipped with dual channel high resolution optical measuring system, integrated computer programming technology and photoelectrical techniques gives reliable results. Tests thin samples or its parts of nonmetallic materials after the coating in research institutes, factories, labs.

Test force 9.8 N, 49 N, 98 N, 196 N, 294 N, 490 N
Hardness value symbol HV1, HV5, HV10, HV20, HV30, HV250
Error range in display ± 3.0 %, ± 2.0 %
Hardness indication Digital display
Hardness value range in Measure 5 HV to 2500 HV
Magnification of Microscope 100x
Loading control Automatic
Pressure holding time 5 to 60 S
Min. measurable unit 0.25 µm
Max. height of sample 160 mm
Distance from intender's center to outer wall 135 mm
Illumination light LED
Main body weight Approx. 40 kg
Dimension of machine 540 × 220 × 650 mm
Power supply AC 220 V, 50 Hz
  • Large LCD display
  • Camera & eyepiece for indention photography & metallography
  • Light source adjustments
  • Soft key input
  • Data recording and data processing
  • RS232 interface for printing output, connection to PC
Digital low load Vickers Hardness tester finds application in research institutes, factories, and quality departments for plastic and other non-metals hardness testing.

NDT Testing Instruments

Portable Vibration Calibrator LPVC-A10

Portable Vibration Calibrator LPVC-A10

  • Frequency (continually adjustable)
  • 10 Hz to1280 Hz + 0.01 %
  • Amplitude acceleration ( at 30m/s2 pk )
  • 40 Hz to 320 Hz + 0.3 dB + 1 digit
  • Amplitude velocity ( at 25mm / sec pk )
  • 40 Hz to 320 Hz + 0.5dB +1 digit
Rockwell hardness meter TRHM-A11

Rockwell hardness meter TRHM-A11

  • Preliminary test force
  • 98 N
  • Total test force
  • 588, 980, 1471 N
  • Total test force dwell time
  • 1 to 30 S
Rockwell hardness meter (motorized type) TRHM-B10

Rockwell hardness meter (motorized type) TRHM-B10

  • Preliminary test force
  • 98 N
  • Total test force
  • 588, 980, 1471 N
  • Brinell hardness test
  • 306, 613, 1839 N
Digital Brinell hardness Tester TDBH-A10

Digital Brinell hardness Tester TDBH-A10

  • Test force
  • 612.5 N, 980 N, 1225 N
  • Brinell hardness test
  • 1837.5 N, 2450 N, 4900 N/7350 N, 9800 N, 14700 N/29400 N
  • Hardness measuring area
  • 8 to 650 HBW (hard metals steel ball)

Paper Testing Instruments

COBB sample cutter TP-C30

COBB sample cutter TP-C30

  • Sample diameter
  • 125 mm
  • Sample error
  • ± 0.2 mm
  • Sample Thickness
  • 0.1 to 1.0 mm
Mullen burst tester TP-K11

Mullen burst tester TP-K11

  • Measurement range
  • 0 to 1600 kPa
  • Accuracy
  • ± 0.5 % F.S.
  • Compression speed
  • 95 ± 5 ml/min
Whiteness meter TP-A11

Whiteness meter TP-A11

  • Sample (size) length
  • Diameter ≥30 mm, Thickness ≤ 40 mm
  • System
  • D/0 lighting geometrical viewing conditions, diffuser diameter (d) 150mm, testing hole diameter 30mm
  • Light source
  • D65 as illuminating source
Internal Ply bond Tester TP-J11

Internal Ply bond Tester TP-J11

  • Capacity
  • A: 20 to 500 J/m2 B: 500 to 1000 J/m2
  • Impact angle
  • 90°
  • Unit
  • Lb-ft/in2  J/m2

Plastic Testing Instruments

Lasting adhesive tester TLAT-A10

Lasting adhesive tester TLAT-A10

  • Standard roller
  • 2000 ± 50 g
  • Testing stations
  • 3
  • Dimension (L*W*H) tester
  • 320×210×550 mm (3 stations)
Aging Oven TAO-A10

Aging Oven TAO-A10

  • The maximum temperature
  • 300°C
  • Temperature fluctuation
  • Within ± 0.5°C
  • Temperature uniformity
  • Within ± 1°C
Heat sealer THS-A10

Heat sealer THS-A10

  • Seal temperature
  • Room temperature -250°C
  • Control accuracy
  • ± 0.2°C
  • Dwell time
  • 0.1 S to 999.9 S
Oxygen Index Tester TOIT-A10

Oxygen Index Tester TOIT-A10

  • Resolution
  • 0.1 % O2
  • Measuring range
  • 0 to 100 % O2
  • Precision
  • ± 0.4 % O2

Rubber Testing Instruments

Rubber low temperature brittleness tester TRBT-A10

Rubber low temperature brittleness tester TRBT-A10

  • Temperature range
  • -60°C to 0°C
  • Temperature accuracy
  • ± 0.5°C
  • Impact speed
  • 2 m/s ± 0.2 m/s
Rubber-weiss plasticity testing machine TRWM-A10

Rubber-weiss plasticity testing machine TRWM-A10

  • Temperature range
  • RT 50° to 300°
  • Temperature accuracy
  • ± 1°
  • Measuring range
  • 0.01 to 25 mm
DIN abrasion tester TDAT-A10

DIN abrasion tester TDAT-A10

  • Test arm weight
  • 2.5 N
  • Additional Loads
  • 2.5 ± 0.1 N, 5 ± 0.1 N, 10 ± 0.1 N,
  • Idler
  • 150 mm
No rotor rheometer TNRR-A10

No rotor rheometer TNRR-A10

  • Temperature tester
  • Room temperature to 200°C
  • Temperature display resolution
  • 0.1°C
  • Temperature control accuracy
  • ≤ ± 0.3°C

Other Testing Instruments

Benchtop gloss meter TBGM-A10

Benchtop gloss meter TBGM-A10

  • Test angle
  • 60°
  • Gloss aperture
  • 2 × 3 mm
  • Measurement range
  • 0 to 1000 GU