Soil water hardness tester TSWH-A11 is a handheld design, model with large backlight LCD display and high resolution to show inverted reverse function of numbers on screen. With high accuracy measurement, it maintains the peak value display until manually zero value adjustment. It holds automatic peak function value on display screen for 2 seconds before automatic elimination.

Maximum load 100 kg ( kg and N can be switched automatically)
Resolution 0.01 g
Accuracy ± 0.5 %
Measuring depth 0 to 450 mm
Environmental temperature 0 to 60°C
Allowable overload 1.5
Memory storage Stores up to 896 groups of data
Power supply mode 5 Nickel Cyanogen
Battery capacity Continuous operated battery, 6 to 8 hrs
Gross weight 13 kg
Power supply Chargeable AC 100 to 240 voltage
  • Large LCD display with backlight function
  • Data output function
  • Data transferrable to PC
  • Large capacity memory storage
  • Gravity acceleration setting function
  • High quality charging power supply
  • Full scale calibration
  • Auto-off time setting 10 to 90 min automatic shutdown
Used for soil water hardness measurement of dry to normal & moist soil for quality analysis & testing purpose.

Soil Testing Instruments

Soil Salinity tester TSST-A10

Soil Salinity tester TSST-A10

  • Salinity Measurement range
  • 0.00 to 19.99 ms/cm
  • Measuring accuracy
  • EC ± 2% full scale
  • Temperature Measurement range
  • -5 to 50°C
Soil moisture meter TSMM-A11

Soil moisture meter TSMM-A11

  • Measurement range
  • 0 to 90 %
  • Resolution
  • 0.1 or 0.01
  • Accuracy
  • ± 5 % n (non-saturation condition)
Soil nutrient tester TSNA-A10

Soil nutrient tester TSNA-A10

  • Measuring range
  • 0.001 to 9999
  • Stability
  • A (absorbency of light)
  • Linearity error
Soil water hardness meter TSHM-A10

Soil water hardness meter TSHM-A10

  • Maximum load
  • 100 kg ( kg and N can be switched automatically)
  • Resolution
  • 0.01 g
  • Accuracy
  • ± 0.5 %

Paper Testing Instruments

Coefficient of friction tester TP-D10

Coefficient of friction tester TP-D10

  • Measurement range
  • 0.01 to 10 N
  • Slider weight
  • 200 g
  • Slider size
  • 63×63 mm
Paper tearing tester TP-J20

Paper tearing tester TP-J20

  • Measuring range
  • 0 to 1000 mN
  • Resolution
  • 0.1 mN
  • Indication error
  • ± 1 %
Ink rubber tester TP-F10

Ink rubber tester TP-F10

  • Sample size (L*B)
  • 230×50 mm (can join short samples together)
  • Rub pressure
  • 20 ± 0.2 N
  • Friction speed
  • 43 times / min
Whiteness and chromaticity tester TP-A10

Whiteness and chromaticity tester TP-A10

  • Sample (size) length
  • Diameter ≥30 mm, Thickness ≤ 40 mm
  • Measurement mode
  • Diffuse reflection factor Rx, Ry, Rz, stimulus value Y10, X10, Z10, chromaticity coordinates x10, y10, z10; lightness L *, chroma a * b *, chroma C * ab, hue angle h * ab, dominant wavelength λd, excitement purity Pe, color difference ΔE * ab, lightness difference ΔL *, chroma difference ΔC * ab, hue difference ΔH * ab, Hunter system L , A, b
  • Stability
  • ≤ 0.1 within 30 min

Plastic Testing Instruments

Lasting adhesive tester TLAT-A10

Lasting adhesive tester TLAT-A10

  • Standard roller
  • 2000 ± 50 g
  • Testing stations
  • 3
  • Dimension (L*W*H) tester
  • 320×210×550 mm (3 stations)
Aging Oven TAO-A10

Aging Oven TAO-A10

  • The maximum temperature
  • 300°C
  • Temperature fluctuation
  • Within ± 0.5°C
  • Temperature uniformity
  • Within ± 1°C
Melt flow Indexer TMFI-A10

Melt flow Indexer TMFI-A10

  • Measuring range
  • 0.01 to 600.00 g/ 10 min (MFR), 0.01 to 600.00 cm/ 10 min (MVR), 0.001 to 9.999 g/cm (melt density)
  • Measuring rate
  • 0.001 S
  • Temperature range
  • 50 to 400°C
Melt flow Indexer TMFI-A11

Melt flow Indexer TMFI-A11

  • Measuring range
  • 0.01to 600.00 g/ 10 min (MFR), 0.01 to 600.00 cm3/ 10 min (MVR), 0.001 to 9.999 g/ cm3 (melt density)
  • Measuring rate
  • 0.001 S
  • Temperature range
  • 50 to 400°C

Rubber Testing Instruments

No rotor rheometer TNRR-A10

No rotor rheometer TNRR-A10

  • Temperature tester
  • Room temperature to 200°C
  • Temperature display resolution
  • 0.1°C
  • Temperature control accuracy
  • ≤ ± 0.3°C
Rubber Low Temperature Brittleness Tester TRBT-A11

Rubber Low Temperature Brittleness Tester TRBT-A11

  • Temperature control range
  • Room temperature to -70 ℃ (room temperature ≤ 25 ℃)
  • Temperature accuracy
  • ± 0.3 ℃
  • Impact speed
  • 0℃ to -30℃ around 2.5 ℃/min '-30℃ to -40℃ around 2.5 ℃/min '-40℃ to -70℃ around 2.0 ℃/min
DIN abrasion tester TDAT-A10

DIN abrasion tester TDAT-A10

  • Test arm weight
  • 2.5 N
  • Additional Loads
  • 2.5 ± 0.1 N, 5 ± 0.1 N, 10 ± 0.1 N,
  • Idler
  • 150 mm
Rubber-weiss plasticity testing machine TRWM-A10

Rubber-weiss plasticity testing machine TRWM-A10

  • Temperature range
  • RT 50° to 300°
  • Temperature accuracy
  • ± 1°
  • Measuring range
  • 0.01 to 25 mm

NDT Testing Instruments

Rockwell hardness meter TRHM-A11

Rockwell hardness meter TRHM-A11

  • Preliminary test force
  • 98 N
  • Total test force
  • 588, 980, 1471 N
  • Total test force dwell time
  • 1 to 30 S
Portable Vibration Calibrator LPVC-A10

Portable Vibration Calibrator LPVC-A10

  • Frequency (continually adjustable)
  • 10 Hz to1280 Hz + 0.01 %
  • Amplitude acceleration ( at 30m/s2 pk )
  • 40 Hz to 320 Hz + 0.3 dB + 1 digit
  • Amplitude velocity ( at 25mm / sec pk )
  • 40 Hz to 320 Hz + 0.5dB +1 digit
Digital low load Vickers Hardness tester TDVH-A10

Digital low load Vickers Hardness tester TDVH-A10

  • Test force
  • 9.8 N, 49 N, 98 N, 196 N, 294 N, 490 N
  • Hardness value symbol
  • HV1, HV5, HV10, HV20, HV30, HV250
  • Error range in display
  • ± 3.0 %, ± 2.0 %
Digital Brinell hardness Tester TDBH-A10

Digital Brinell hardness Tester TDBH-A10

  • Test force
  • 612.5 N, 980 N, 1225 N
  • Brinell hardness test
  • 1837.5 N, 2450 N, 4900 N/7350 N, 9800 N, 14700 N/29400 N
  • Hardness measuring area
  • 8 to 650 HBW (hard metals steel ball)