Soil nutrient tester TSNA-A10 with microprocessor controlled technology measures nutrient values in % and gives accurate test results. Its LCD touch display shows all test parameters, test results, which can be printed out using built-in printer. The optical filter present in the nutrient analyzer acts as light source, its silicon semiconductor acts as signal receiver system with 100000 hours of work life.

Measuring range 0.001 to 9999
Stability A (absorbency of light) <0.003 within 3 mins
Linearity error <3.0 %
Repeatability error A (absorbency of light) <0.005
Wavelength range Red light: 680 ± 2 nm, Blue light: 420 ± 2 nm, Green light: 510 ± 2 nm, Orange light: 590 ± 2 nm
Sensitivity Red light: ≥ 4.5 × 10<sup>-5</sup> , Blue light: ≥ 3.17 × 10<sup>-3</sup> , Green light: ≥ 2.35 × 10<sup>-3</sup> , Orange light: ≥ 2.13 × 10<sup>-3</sup>
Moisture measure range A: humidity 0 to 100 %, B: Accuracy: ±3 %
Measurement time (for soil N, P, K) ≤30 min<br/> 5 pcs soil samples at one time ≤50 min (including pretreatment time)
Soil moisture mode <table class='table table-striped table-bordered table-responsive'><tr><td><strong>Moisture content rate testing range</strong></td><td>0 to 100 %</td></tr><tr><td><strong>Moisture unit</strong></td><td>% (m<sup>3</sup>/m<sup>3</sup>)</td></tr><tr><td><strong>Accuracy</strong></td><td>± 2 %</td></tr></table>
pH mode <table class='table table-striped table-bordered table-responsive'><tr><td><strong>pH Measurement range</strong></td><td>1 to 14 pH</td></tr><tr><td><strong>pH Accuracy</strong></td><td>± 0.1</td></tr></table>
Conductivity mode <table class='table table-striped table-bordered table-responsive'><tr><td><strong>Conductivity Measurement range</strong></td><td>0.01 % to 1.00 %</td></tr><tr><td><strong>Conductivity Accuracy</strong></td><td>± 5 %</td></tr></table>
Dimension 340 × 280 × 100 mm
Gross Weight 15 kg
Power supply AC 180 to 240 V, 50 Hz
  • LCD display touch control
  • Microprocessor controlled technology
  • Built-in thermal printer
  • Automatic temperature calibration system for organic phosphorous testing
  • Excellent shock resistant
  • Digital circuit programmed design
It finds best application in quantitative analysis of to N, P, K, organic matter, pH, trace elements, salinity of soil, fertilizer & other samples.

Soil Testing Instruments

Soil moisture meter TSMM-A11

Soil moisture meter TSMM-A11

  • Measurement range
  • 0 to 90 %
  • Resolution
  • 0.1 or 0.01
  • Accuracy
  • ± 5 % n (non-saturation condition)
Soil moisture meter TSMM-A12

Soil moisture meter TSMM-A12

  • Measurement range
  • 0 to 60 %
  • Resolution
  • 0.1
  • Accuracy
  • ± 5 % n (non-saturation condition)
Soil moisture meter TSMM-A10

Soil moisture meter TSMM-A10

  • Measurement range
  • 0 to 80 %
  • Resolution
  • 0.1
  • Accuracy
  • ± 2 % n (non-saturation condition)
Soil Water potential tester TSWT-A10

Soil Water potential tester TSWT-A10

  • Measuring range
  • 0 to 100 kPa
  • Resolution
  • 0.01 kPa
  • Accuracy
  • ± 1 kPa

Paper Testing Instruments

Puncture strength tester TP-J12

Puncture strength tester TP-J12

  • Measuring range
  • A (1 to 6) J indicating error ± 0.05 J B (1 to 12) J indicating error ± 0.05 J C (1 to 24) J indicating error ± 0.05 J D (1 to 48) J indicating error ± 0.05 J The indicating errors w.r.t measurement range of 20 to 80 %
  • Frictional resistance
  • Pyramid dimension
  • Three sides: 60×60×60 mm, height 25 ± 0.7 mm, Arris edge fillet radius 1.5 ± 0.1 mm
Folding endurance tester TP-M10

Folding endurance tester TP-M10

  • Measuring scope
  • 0 to 99999 s
  • Folding angle
  • 135° ± 2°
  • Tensile scope
  • 4.9 to 14.7 N
Softness tester TP-H10

Softness tester TP-H10

  • Measuring range
  • 10 to 1000 mN
  • Division value
  • 1 mN
  • Accuracy
  • ± 1%
Paper and cardboard thickness meter TP-E21

Paper and cardboard thickness meter TP-E21

  • Measuring range
  • 0 to 20 mm
  • Accuracy
  • 0.01 mm
  • Gauge
  • Analogue gauge display

Plastic Testing Instruments

Vacuum Leak Tester TVLT-A10

Vacuum Leak Tester TVLT-A10

  • Vacuum degree
  • 0 to 90 KPa
  • Accuracy
  • 1 % FS
  • Resolution
  • 0.1 KPa
Heat sealer THS-A10

Heat sealer THS-A10

  • Seal temperature
  • Room temperature -250°C
  • Control accuracy
  • ± 0.2°C
  • Dwell time
  • 0.1 S to 999.9 S
Primary adhesive tester TPAT-A10

Primary adhesive tester TPAT-A10

  • Inclined adjustable angle
  • 0 to 40°
  • Panel width
  • 120 mm
  • Test area width
  • 80 mm
Falling Weight Impact Tester TFWT-A10

Falling Weight Impact Tester TFWT-A10

  • Temperature range
  • 10 to 35°C
  • Maximum falling height
  • 2000 mm
  • Resolution of displacement
  • 1 mm

Rubber Testing Instruments

No rotor rheometer TNRR-A10

No rotor rheometer TNRR-A10

  • Temperature tester
  • Room temperature to 200°C
  • Temperature display resolution
  • 0.1°C
  • Temperature control accuracy
  • ≤ ± 0.3°C
DIN abrasion tester TDAT-A10

DIN abrasion tester TDAT-A10

  • Test arm weight
  • 2.5 N
  • Additional Loads
  • 2.5 ± 0.1 N, 5 ± 0.1 N, 10 ± 0.1 N,
  • Idler
  • 150 mm
Rubber-weiss plasticity testing machine TRWM-A10

Rubber-weiss plasticity testing machine TRWM-A10

  • Temperature range
  • RT 50° to 300°
  • Temperature accuracy
  • ± 1°
  • Measuring range
  • 0.01 to 25 mm
Three roll mill machine TRMM-A10

Three roll mill machine TRMM-A10

  • Mixed capacity
  • 0.5 to 1 kg, 2 to 3 kg, 5 to 7 kg
  • Temperature range
  • RT to 300°C
  • Temperature control system
  • PID control

NDT Testing Instruments

Rockwell hardness meter TRHM-A11

Rockwell hardness meter TRHM-A11

  • Preliminary test force
  • 98 N
  • Total test force
  • 588, 980, 1471 N
  • Total test force dwell time
  • 1 to 30 S
Portable Vibration Calibrator LPVC-A10

Portable Vibration Calibrator LPVC-A10

  • Frequency (continually adjustable)
  • 10 Hz to1280 Hz + 0.01 %
  • Amplitude acceleration ( at 30m/s2 pk )
  • 40 Hz to 320 Hz + 0.3 dB + 1 digit
  • Amplitude velocity ( at 25mm / sec pk )
  • 40 Hz to 320 Hz + 0.5dB +1 digit
Rockwell hardness meter TRHM-A10

Rockwell hardness meter TRHM-A10

  • Preliminary test force
  • 98 N
  • Total test force
  • 588, 980, 1471 N
  • Total test force dwell time
  • 0 to 30 S
Digital low load Vickers Hardness tester TDVH-A10

Digital low load Vickers Hardness tester TDVH-A10

  • Test force
  • 9.8 N, 49 N, 98 N, 196 N, 294 N, 490 N
  • Hardness value symbol
  • HV1, HV5, HV10, HV20, HV30, HV250
  • Error range in display
  • ± 3.0 %, ± 2.0 %